14 CAR pt. 21, Appendix D
14 CAR pt. 21, Appendix D. Requirements for the Approval of Residential Aerobic Treatment Units for Distribution in Arkansas
Length: 262 wordsOfficial source
Appendix D
Requirements for the Approval of Residential Aerobic Treatment Units for Distribution in
Arkansas.
Aerobic Treatment Units may be used for treating domestic wastewater waste, provided that
each unit is installed, operated and maintained in conformance with the following provisions:
1. Aerobic treatment systems designed to treat up to 2,000 gallons of wastewater waste per day
shall be tested and listed by an American National Standards Institute (ANSI) certified third
party previously approved by the Department. Aerobic treatment units shall be in compliance
with the standards for Class I systems as defined by the ANSI/NSF Standard Number 40
(revised 2005).
2. The following additional requirements shall also apply to the construction, design, and
operation of aerobic treatment units treating 2,000 gallons per day or less:
a. A visual and audio warning device shall be installed in a conspicuous location so that
activation of the warning device will alert property occupants of aerobic unit malfunction or
failure. The wiring device shall be wired separately from the ATU so that disconnecting the ATU
from the electrical supply will activate the alarm.
b. Each unit shall be designed or equipped so that regardless of unusual patterns or
frequencies of wastewater flow into the system effluent discharged will be in compliance with
Class I effluent quality standards as defined by the General NPDES Permit ARG550000,
Discharges from Individual Home Treatment Facilities.
c. The minimum required treatment capacities for systems serving any structure, building
or group of buildings; shall be based on estimated daily wastewater flows as determined by the
Rules Pertaining to Onsite Wastewater Systems.