8 CAR § 41-704
8 CAR § 41-704. Kraft pulp mills
Length: 477 wordsOfficial source
(a) Subsections (b) and (c) of this section and the total reduced sulfur emissions limitations contained in Table 41.7.1 are applicable to equipment located at the following kraft pulp mills:
(1) Evergreen Packaging (AFIN 35-00016);
(2) Green Bay Packaging, Arkansas Kraft Division (AFIN 15-00001);
(3) Twin Rivers Pine Bluff, LLC (AFIN 35-00017);
(4) Georgia-Pacific Corporation (AFIN 02-00013);
(5) Domtar A.W. (AFIN 41-00002); and
(6) Clearwater Paper Corporation (AFIN 21-00036).
(b)(1) The owner or operator of designated facilities listed in Table 41.7.1 shall test compliance with total reduced sulfur emissions limitations using EPA Method 16 at intervals of no longer than five (5) years following the previous compliance test.
(2) Data reduction shall be performed as set forth in 40 C.F.R. § 60.8.
(3) Compliance testing is not required for equipment with a total reduced sulfur continuous emissions monitor.
(c)(1) The owner or operator of any equipment located at the designated facilities specified under subsection (a) of this section shall conduct total reduced sulfur continuous monitoring in accordance with the requirements of 40 C.F.R. § 60.284, date of installation notwithstanding.
(2) The continuous monitoring systems shall be operated according to the provisions of 40 C.F.R. § 60.284 by April 1, 1993, except that continuous emissions monitors for affected lime kilns shall be installed and certified by January 1, 1994.
Table 41.7.1 Kraft Pulp Mill TRS Emission Limits
AFIN
Facility
Equipment
TRS Concentration (parts per million [ppm])
35-
00016
Twin Rivers Pine Bluff, LLC
recovery furnace
Forty million
(40)
parts
per
lime kiln
Forty million
(40)
parts
per
smelt dissolving tank
0.0168 grams per kilogram
15-
00001
Green Bay Packaging, Arkansas Kraft Division
recovery furnace
Forty million
(40)
parts
per
lime kiln
Forty million
(40)
parts
per
smelt dissolving tank
0.0168 grams per kilogram
35-
00017
Mondi Pine Bluff
recovery furnace
One hundred (100) parts per million
lime kiln
Forty million
(40)
parts
per
smelt dissolving tank
0.0168 grams per kilogram
02-
00013
Georgia Pacific Corporation
recovery furnace
Five (5) parts per million
lime kiln
Eight (8) parts per million
smelt dissolving tank
0.0168 grams per kilogram
41-
00002
Domtar A.W.
recovery furnace
Five (5)parts per million
lime kiln
Eight (8) parts per million
smelt dissolving tank
0.0168 grams per kilogram
21-
00036
Clearwater Paper Corporation
recovery furnace
Five (5) parts per million
lime kiln
Twenty (20) parts per million
smelt dissolving tank
0.0168 grams per kilogram
Recovery Furnaces–measured as hydrogen sulfide on a dry basis and on a twelve-hour average, corrected to eight percent (8%) by volume oxygen.
Lime Kilns–measured as hydrogen sulfide on a dry basis and on a twelve-hour average, corrected to ten percent (10%) volume oxygen.
Smelt Dissolving Tanks–measured as grams hydrogen sulfide per kilogram black liquor solids on a twelve-hour average.
Digesters and Evaporators–efficient incineration of non-condensable gases (at least twelve hundred degrees Fahrenheit [1200°F] for at least one-half [0.5] of one [1] second).