R.C.S.A. § 25-128-57
Procedure of abandonment
Cite as Conn. Agencies Regs. § 25-128-57
In the event of abandonment of any water well or other type of well the proper procedure
and materials shall be used as follows:
(a) The well shall be plugged to prevent the entrance of surface water, circulation of
water between or among producing zones, or any other process resulting in the contamination
or pollution of ground water resources.
(b) In the event of temporary abandonment or discontinuance of the use of any well, the
well shall be sealed with a watertight cap or seal, as provided by Section 25-128-42
(c).
(c) The well shall be chlorinated prior to abandonment using a chlorine solution with
a minimum concentration of one hundred fifty parts per million (150 ppm) of chlorine.
This is equivalent to 5.5 quarts of bleach at 2.25% available chlorine to five hundred
(500) gallons of water or three hundred thirty-three (333) feet of six (6) inch diameter
well.
(d) The well shall be checked from land surface to the entire depth of the well before
it is sealed, to insure against the presence of any obstruction that will interfere
with sealing operations.
(e) The well bore shall be filled and sealed with any of the following materials: heat
cement grout, sand cement grout, bentonite clay grout, or sand clay or bentonite cement
grout.
(f) The grout material shall be placed in such a way to prevent voids in the grout or
dilution of the grout.
(g) Any well constructed in a consolidated rock formation, may be filled with fine sand
in the zone or zones of consolidated rock. The top of the sand fill shall be at least
ten (10) feet below the bottom of the casing, and the remaining portions of the well
shall be filled with any of the materials specified in subsection (e).
(h) Any test well or bore shall be abandoned in such a manner that it does not become
a channel for the vertical movement of water or other substance to the potable ground
water resources.
(i) Deep waste disposal or oil wells with casings free of any breaks, and extending below
the potable ground water zones, may be sealed with a watertight cap or welded plate.
(j) Upon completion of abandonment of the well, the top of the casing or grout material
may be terminated at least four (4) feet below the ground surface.