(a) Types of operation. Operation of the platform from the upper or lower landings and on the platform shall
be controlled by a key. The key operated control shall be operated by a lock having
five (5) pins with the key removable only from the "off" position. A key switch shall
be provided at each station which will allow a control switch at that station to become
effective only when the key is in the "on" position. "Up" and "down" control switches
at all stations shall be by means of a constant pressure device.
(b) Control and operating circuit requirements. The design and installation of the control and operating circuits shall conform to
the following:
(1) Control systems which depend on the completion or maintenance of an electric circuit
shall not be used for:
A. Interruption of the power and application of the machine brake at terminals.
B. Stopping the machine when the safety applies.
(2) If springs are used to actuate switches, contractors, or relays to break the circuit
to stop an elevator at the terminal, they shall be of the restrained compression type.
(3) The failure of any single magnetically operated switch, relay or contractor, to release
in the intended manner or the occurrence of a single accidental ground shall not permit
the car to start if the hoistway door or platform door or gate is not in the closed
position. It shall not permit the platform to move more than two inches away from
a floor with the entrance door unlocked.