Where a court is provided, it shall have the following minimum dimensions:
TABLE I § 207.1: MINIMUM COURT DIMENSIONS
Type of Structure Minimum Width Open Court Minimum Width Closed Court Minimum Area Closed Court
Residential, more than 3 units
4 in./ ft. of height of court;
10 ft. minimum
4 in./ft. of height of court;
15 ft. minimum
Twice the square of the required width of court dimension;
350 sq. ft. minimum
Non-Residential and Lodging
2.5in./ft. of height of court;
6 ft. minimum
2.5 in./ft. of height of court;
12 ft. minimum
Twice the square of the required width of court dimension;
250 sq. ft. minimum.
SOURCE: Final Rulemaking published at 63 DCR 2447, 3041 (March 4, 2016 – Part 2); as amended by Final Rulemaking published at 63 DCR 10932 (August 26, 2016); as amended by Final Rulemaking published at 64 DCR 22 (January 6, 2017).