Where a court is provided, it shall have the following minimum dimensions:
TABLE K § 227.1: MINIMUM COUTYARD DIMENSIONS
Type of Structure Minimum Width Open Court Minimum Width Closed Court Minimum Area Closed Court Residential (except hotel): 4 in./ft. of height of court;
10 ft. minimum. 4 in./ft. of height of court;
15 ft. minimum. Twice the square of the required width of court dimension;
350 sq. ft. minimum. Non-Residential and Lodging: 2.5 in./ft. of height of court;
6 ft. minimum. 2.5 in./ft. of height of court;
12 ft. min. Twice the square of the required width of court dimension;
250 sq. ft. minimum.