Medicare National Coverage Determinations (NCD) Manual (Pub. 100-03), Ch. 1 § 20.15
Electrocardiographic Services
20.15 – Electrocardiographic Services
(Rev. 173, Issued: 09-04-14, Effective: Upon Implementation: of ICD-10,
Implementation: Upon Implementation of ICD- 10)
A.
General
1.
An electrocardiogram (EKG) is a graphic representation of electrical activity within
the heart. Electrodes placed on the body in predetermined locations sense this electrical
activity, which is then recorded by various means for review and interpretation. EKG
recordings are used to diagnose a wide range of heart disease and other conditions that
manifest themselves by abnormal cardiac electrical activity.
EKG services are covered diagnostic tests when there are documented signs and
symptoms or other clinical indications for providing the service. Coverage includes the
review and interpretation of EKGs only by a physician. There is no coverage for EKG
services when rendered as a screening test or as part of a routine examination unless
performed as part of the one-time, “Welcome to Medicare” preventive physical
examination under section 611 of the Medicare Prescription Drug, Improvement, and
Modernization Act of 2003.
2.
Ambulatory electrocardiography (AECG) refers to services rendered in an
outpatient setting over a specified period of time, generally while a patient is engaged in
daily activities, including sleep. AECG devices are intended to provide the physician with
documented episodes of arrhythmia, which may not be detected using a standard 12-lead
EKG. AECG is most typically used to evaluate symptoms that may correlate with
intermittent cardiac arrhythmias and/or myocardial ischemia. Such symptoms include
syncope, dizziness, chest pain, palpitations, or shortness of breath. Additionally, AECG
is used to evaluate patient response to initiation, revision, or discontinuation of
arrhythmic drug therapy.
3.
The Centers for Medicare & Medicaid Services (CMS), through the national
coverage determination (NCD) process, may create new ambulatory EKG monitoring
device categories if published, peer-reviewed clinical studies demonstrate evidence of
improved clinical utility, or equal utility with additional advantage to the patient, as
indicated by improved patient management and/or improved health outcomes in the
Medicare population (such as superior ability to detect serious or life-threatening
arrhythmias) as compared to devices or services in the currently described categories
below.
Descriptions of Ambulatory EKG Monitoring Technologies
1.
Dynamic electrocardiography devices that continuously record a real-time EKG,
commonly known as Holter™ monitors, typically record over a 24-hour period. The
recording is captured either on a magnetic tape or other digital medium. The data is then
computer-analyzed at a later time, and a physician interprets the computer-generated
report. A 24-hour recording is generally adequate to detect most transient arrhythmias.
Documentation of medical necessity is required for monitoring longer than 24 hours. The
recording device itself is not covered as durable medical equipment (DME) separate from
the total diagnostic service.
2.
An event monitor, or event recorder, is a patient-activated or event-activated EKG
device that intermittently records cardiac arrhythmic events as they occur. The EKG is
recorded on magnetic tape or other digital medium.
Cardiac event monitor technology varies among different devices. For patient-activated
event monitors, the patient initiates recording when symptoms appear or when instructed
to do so by a physician (e.g., following exercise). For self-sensing, automatically
triggered monitors, an EKG is automatically recorded when the device detects an
arrhythmia, without patient intervention. Some devices permit a patient to transmit EKG
data transtelephonically (i.e., via telephone) to a receiving center where the data is
reviewed. A technician may be available at these centers to review transmitted data 24
hours per day. In some instances, when the EKG is determined to be outside certain pre-
set criteria by a technician or other non-physician, a physician is available 24 hours per
day to review the transmitted data and to make clinical decisions regarding the patient.
These services are known as “24-hour attended monitoring”. In other instances,
transmitted EKG data is reviewed at a later time and are, therefore, considered “non-
attended.”
Cardiac event monitors without transtelephonic capability must be removed from the
patient and taken to a location for review of the stored EKG data. Some devices also
permit a "time sampling" mode of operation. The "time sampling" mode is not covered
under ambulatory EKG monitoring technology. Some cardiac event monitoring devices
with trans-telephonic capabilities require the patient to dial the phone number of a central
EKG data reception center and initiate transmission of EKG data. Other devices use
Internet-based in-home computers to capture and store EKG data. When such devices
detect pre-programmed arrhythmias, data is automatically sent via modem and standard
telephone lines to a central receiving center, or independent diagnostic testing facility
(IDTF), where the data is reviewed. Internet-based in-home computer systems may also
provide the receiving center with a daily computer-generated report that summarizes 24
hours of EKG data.
Certain cardiac event monitors capture electrical activity with a single electrode attached
to the skin. Other devices may employ multiple electrodes in order to record more
complex EKG tracings. Additionally, devices may be individually programmed to detect
patient-specific factors, electrode malfunction, or other factors. Cardiac event monitors
can be further categorized as either “pre-event” or “post-event” recorders, based on their
memory capabilities:
a.
Pre-symptom Memory Loop Recorder (MLR)
Upon detecting symptoms, the wearer presses a button, which activates the recorder to
save (i.e., memorize) an interval of pre-symptom EKG data along with data during and
subsequent to the symptomatic event. Self-sensing recorders (also known as event-
activated or automatic trigger) do not require patient input to capture these data. Single
or multiple events may be recorded. The device is worn at all times, usually for up to 30
days.
o Implantable (or Insertable Loop) Recorder (ILR)
Another type of pre-symptom MLR, it is implanted subcutaneously in a patient’s upper
left chest and may remain implanted for many months. An ILR is used when syncope is
thought to be cardiac-related, but is too infrequent to be detected by either a Holter™
monitor or a traditional pre-symptom MLR.
b.
Post-symptom Recorder
The patient temporarily places this device against the chest when symptoms occur and
activates it by pressing a button. These recorders represent old technology, as they do not
include a memory loop. The device transmits EKG data telephonically in real-time and is
usually used for up to 30 days.
B. Nationally Covered Indications
The following indications are covered nationally unless otherwise indicated:
1.
Computer analysis of EKGs when furnished in a setting and under the
circumstances required for coverage of other EKG services.
2.
EKG services rendered by an IDTF, including physician review and interpretation.
Separate physician services are not covered unless he/she is the patient’s attending or
consulting physician.
3.
Emergency EKGs (i.e., when the patient is or may be experiencing a life-
threatening event) performed as a laboratory or diagnostic service by a portable x-ray
supplier only when a physician is in attendance at the time the service is performed or
immediately thereafter.
4
Home EKG services with documentation of medical necessity.
5.
Transtelephonic EKG transmissions (effective March 1, 1980) as a diagnostic
service for the indications described below, when performed with equipment meeting the
standards described below, subject to the limitations and conditions specified below.
Coverage is further limited to the amounts payable with respect to the physician’s service
in interpreting the results of such transmissions, including charges for rental of the
equipment. The device used by the beneficiary is part of a total diagnostic system and is
not considered DME separately. Covered uses are to:
a. Detect, characterize, and document symptomatic transient arrhythmias;
b. Initiate, revise, or discontinue arrhythmic drug therapy; or,
c. Carry-out early post-hospital monitoring of patients discharged after myocardial
infarction (MI); (only if 24-hour coverage is provided, see C.5. below).
Certain uses other than those specified above may be covered if, in the judgment of the
local A/B MAC, such use is medically necessary.
Additionally, the transmitting devices must meet at least the following criteria:
a. They must be capable of transmitting EKG Leads, I, II, or III; and,
b. The tracing must be sufficiently comparable to a conventional EKG.
24-hour attended coverage used as early post-hospital monitoring of patients discharged
after MI is only covered if provision is made for such 24-hour attended coverage in the
manner described below:
24-hour attended coverage means there must be, at a monitoring site or central data
center, an EKG technician or other non-physician, receiving calls and/or EKG data; tape
recording devices do not meet this requirement. Further, such technicians should have
immediate, 24-hour access to a physician to review transmitted data and make clinical
decisions regarding the patient. The technician should also be instructed as to when and
how to contact available facilities to assist the patient in case of emergencies.
C.
Nationally Non-Covered Indications
The following indications are non-covered nationally unless otherwise specified below:
1.
The time-sampling mode of operation of ambulatory EKG cardiac event
monitoring/recording.
2.
Separate physician services other than those rendered by an IDTF unless rendered
by the patient’s attending or consulting physician.
3.
Home EKG services without documentation of medical necessity.
4.
Emergency EKG services by a portable x-ray supplier without a physician in
attendance at the time of service or immediately thereafter.
5.
24-hour attended coverage used as early post-hospital monitoring of patients
discharged after MI unless provision is made for such 24-hour attended coverage in the
manner described in section B.5. above.
6.
Any marketed Food and Drug Administration (FDA)-approved ambulatory cardiac
monitoring device or service that cannot be categorized according to the framework
below.
D.
Other
Ambulatory cardiac monitoring performed with a marketed, FDA-approved device, is
eligible for coverage if it can be categorized according to the framework below. Unless
there is a specific NCD for that device or service, determination as to whether a device or
service that fits into the framework is reasonable and necessary is according to local A/B
MAC discretion.
Electrocardiographic Services Framework
Attended
Pre-symptom memory loop
● Insertable
Non-attended
● Non-insertable
Patient/Event-Activated
Intermittent Recorders
Post-symptom (no memory loop) _____ Non-attended
Non-Activated
Continuous Recorders ________Dynamic Electrocardiography _______ Non-attended
(e.g., Holter™ Monitor)