Medicare National Coverage Determinations (NCD) Manual (Pub. 100-03), Ch. 1 § 20.30
Microvolt T-Wave Alternans (MTWA)
20.30 - Microvolt T-Wave Alternans (MTWA)
(Rev. 182, Issued: 05-22-15, Effective: 01-13-15, Implementation: 06-23-15)
A.
General
Microvolt T-wave Alternans (MTWA) testing is a non-invasive diagnostic test that
detects minute electrical activity in a portion of the electrocardiogram (ECG) known as
the T-wave. MTWA testing has a role in the stratification of patients who may be at risk
for sudden cardiac death (SCD) from ventricular arrhythmias.
Within patient groups that may be considered candidates for implantable cardioverter
defibrillator (ICD) therapy, a negative MTWA test may be useful in identifying low-risk
patients who are unlikely to benefit from, and who may experience worse outcomes from,
ICD placement.
Spectral analysis (SA) is a sensitive mathematical method of measuring and comparing
time and the ECG signals. It requires specialized propriety electrodes to calculate minute
T-wave voltage changes. Software then analyzes these microvolt changes and produces a
report to be interpreted by a physician. The Modified Moving Average (MMA) method
uses a temporal domain in which T-wave alternans are assessed as a continuous variable
along the complete ECG. The MMA method of MTWA testing is performed using
standard ambulatory ECG equipment.
B.
Nationally Covered Indications
Effective for dates of service on and after March 21, 2006, MTWA diagnostic testing is
covered for the evaluation of patients at risk for SCD, only when the SA method is used.
C.
Nationally Non-Covered Indications
N/A
D.
Other
Effective for dates of service on and after January 21, 2015, A/B MACs acting within
their respective jurisdictions may determine coverage of MTWA diagnostic testing for
the evaluation of patients at risk for SCD using all other methods.
(This NCD last reviewed January 2015.)