Federal (United States) · Regulations
Subpart KKKKa — Standards of Performance for Stationary Combustion Turbines
28 sections
28 sections
- 40 C.F.R. § 60.4300aWhat is the purpose of this subpart?
- 40 C.F.R. § 60.4305aDoes this subpart apply to my stationary combustion turbine?
- 40 C.F.R. § 60.4315aWhat pollutants are regulated by this subpart?
- 40 C.F.R. § 60.4320aWhat NO X emissions standard must I meet?
- 40 C.F.R. § 60.4325aWhat emission limit must I meet for NO X if my turbine burns both natural gas and distillate oil (or some other combination of fuels)?
- 40 C.F.R. § 60.4330aWhat SO 2 emissions standard must I meet?
- 40 C.F.R. § 60.4335aHow do I demonstrate compliance with my NO X emissions standard without using a NO X CEMS if I use water or steam injection?
- 40 C.F.R. § 60.4340aHow do I demonstrate compliance with my NO X emissions standard without using a NO X CEMS if I do not use water or steam injection?
- 40 C.F.R. § 60.4342aHow do I monitor NO X control operating parameters?
- 40 C.F.R. § 60.4345aHow do I demonstrate compliance with my NO X emissions standard using a NO X CEMS?
- 40 C.F.R. § 60.4350aHow do I use the NO X CEMS data to determine excess emissions?
- 40 C.F.R. § 60.4360aHow do I use fuel sulfur analysis to determine the total sulfur content of the fuel combusted in my stationary combustion turbine?
- 40 C.F.R. § 60.4370aHow frequently must I determine the fuel sulfur content?
- 40 C.F.R. § 60.4372aHow can I demonstrate compliance with my SO 2 emissions standard using records of the fuel sulfur content?
- 40 C.F.R. § 60.4374aHow do I demonstrate compliance with my SO 2 emissions standard and determine excess emissions using a SO 2 CEMS?
- 40 C.F.R. § 60.4375aWhat reports must I submit?
- 40 C.F.R. § 60.4380aHow are NO X excess emissions and monitor downtime reported?
- 40 C.F.R. § 60.4385aHow are SO 2 excess emissions and monitor downtime reported?
- 40 C.F.R. § 60.4390aWhat records must I maintain?
- 40 C.F.R. § 60.4395aWhen must I submit my reports?
- 40 C.F.R. § 60.4400aHow do I conduct performance tests to demonstrate compliance with my NO X emissions standard if I do not have a NO X CEMS?
- 40 C.F.R. § 60.4405aHow do I conduct a performance test if I use a NO X CEMS?
- 40 C.F.R. § 60.4416aWhat parts of the general provisions apply to my affected EGU?
- 40 C.F.R. § 60.4417aWho implements and enforces this subpart?
- 40 C.F.R. § 60.4420aWhat definitions apply to this subpart?
- 40 C.F.R. Table 1 to Subpart KKKKa of Part 60Table 1 to Subpart KKKK a of Part 60—Nitrogen Oxide Emission Standards for Stationary Combustion Turbines
- 40 C.F.R. Table 2 to Subpart KKKKa of Part 60Table 2 to Subpart KKKK a of Part 60—Alternative Mass-Based NO X Emission Standards for Stationary Combustion Turbines
- 40 C.F.R. Table 3 to Subpart KKKKa of Part 60Table 3 to Subpart KKKK a of Part 60—Applicability of Subpart A of This Part to This Subpart