Federal (United States) · Regulations
Subpart LLL — Federal Plan Requirements for Sewage Sludge Incineration Units Constructed on or Before October 14, 2010
44 sections
44 sections
- 40 C.F.R. § 62.15855Am I subject to this subpart?
- 40 C.F.R. § 62.15860What SSI units are exempt from the federal plan?
- 40 C.F.R. § 62.15865How do I determine if my SSI unit is covered by an approved and effective state or tribal plan?
- 40 C.F.R. § 62.15870If my SSI unit is not listed on the federal plan inventory, am I exempt from this subpart?
- 40 C.F.R. § 62.15875What is my final compliance date?
- 40 C.F.R. § 62.15885What must I include in the notifications of achievement of compliance?
- 40 C.F.R. § 62.15890When must I submit the notifications of achievement of compliance?
- 40 C.F.R. § 62.15895What if I do not meet the compliance date?
- 40 C.F.R. § 62.15900How do I comply with the requirement for submittal of a control plan?
- 40 C.F.R. § 62.15905How do I achieve final compliance?
- 40 C.F.R. § 62.15910What must I do if I close my SSI unit and then restart it?
- 40 C.F.R. § 62.15915What must I do if I plan to permanently close my SSI unit and not restart it?
- 40 C.F.R. § 62.15920What are the operator training and qualification requirements?
- 40 C.F.R. § 62.15925When must the operator training course be completed?
- 40 C.F.R. § 62.15930How do I obtain my operator qualification?
- 40 C.F.R. § 62.15935How do I maintain my operator qualification?
- 40 C.F.R. § 62.15940How do I renew my lapsed operator qualification?
- 40 C.F.R. § 62.15945What if all the qualified operators are temporarily not accessible?
- 40 C.F.R. § 62.15950What site-specific documentation is required and how often must it be reviewed by qualified operators and plant personnel?
- 40 C.F.R. § 62.15955What emission limits and standards must I meet and by when?
- 40 C.F.R. § 62.15960What operating limits and requirements must I meet and by when?
- 40 C.F.R. § 62.15965How do I establish operating limits if I do not use a wet scrubber, fabric filter, electrostatic precipitator, activated carbon injection, or afterburner, or if I limit emissions in some other manner, to comply with the emission limits?
- 40 C.F.R. § 62.15970Do the emission limits, emission standards, and operating limits apply during periods of startup, shutdown, and malfunction?
- 40 C.F.R. § 62.15980How and when do I demonstrate initial compliance with the emission limits and standards?
- 40 C.F.R. § 62.15985How do I establish my operating limits?
- 40 C.F.R. § 62.15990By what date must I conduct the initial air pollution control device inspection and make any necessary repairs?
- 40 C.F.R. § 62.15995How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection, and ash handling systems, and by what date must I conduct an initial performance evaluation?
- 40 C.F.R. § 62.16000How and when do I demonstrate continuous compliance with the emission limits and standards?
- 40 C.F.R. § 62.16005How do I demonstrate continuous compliance with my operating limits?
- 40 C.F.R. § 62.16010By what date must I conduct annual air pollution control device inspections and make any necessary repairs?
- 40 C.F.R. § 62.16015What are the performance testing, monitoring, and calibration requirements for compliance with the emission limits and standards?
- 40 C.F.R. § 62.16020What are the monitoring and calibration requirements for compliance with my operating limits?
- 40 C.F.R. § 62.16025What records must I keep?
- 40 C.F.R. § 62.16030What reports must I submit?
- 40 C.F.R. § 62.16035Am I required to apply for and obtain a title V operating permit for my existing SSI unit?
- 40 C.F.R. § 62.16040When must I submit a title V permit application for my existing SSI unit?
- 40 C.F.R. § 62.16045What definitions must I know?
- 40 C.F.R. § 62.16050What authorities will be retained by the EPA Administrator?
- 40 C.F.R. Table 1 to Subpart LLL of Part 62Compliance Schedule for Existing Sewage Sludge Incineration Units
- 40 C.F.R. Table 2 to Subpart LLL of Part 62Emission Limits and Standards for Existing Fluidized Bed Sewage Sludge Incineration Units
- 40 C.F.R. Table 3 to Subpart LLL of Part 62Emission Limits and Standards for Existing Multiple Hearth Sewage Sludge Incineration Units
- 40 C.F.R. Table 4 to Subpart LLL of Part 62Operating Parameters for Existing Sewage Sludge Incineration Units 1
- 40 C.F.R. Table 5 to Subpart LLL of Part 62Toxic Equivalency Factors
- 40 C.F.R. Table 6 to Subpart LLL of Part 62Summary of Reporting Requirements for Existing Sewage Sludge Incineration Units 1