40 C.F.R. § 1065.277

NH 3 measurement devices.

Last amended: 2024Year: 2026Length: 378 wordsSubsections: 1Official source

Cite as 40 C.F.R. § 1065.277 (2026)

(a) General component requirements. We recommend that you use an analyzer that meets the specifications in § 1065.205. Note that your system must meet the linearity verification in § 1065.307. (b) Instrument types. You may use any of the following analyzers to measure NH 3 : (1) Nondispersive ultraviolet (NDUV) analyzer. (2) Fourier transform infrared (FTIR) analyzer. Use appropriate analytical procedures for interpretation of infrared spectra. For example, EPA Test Method 320 (see § 1065.266(c)) and ASTM D6348 (incorporated by reference, see § 1065.1010) are considered valid methods for spectral interpretation. (3) Laser infrared analyzer. Examples of laser infrared analyzers are pulsed-mode high-resolution narrow-band mid-infrared analyzers, modulated continuous wave high-resolution narrow band near and mid-infrared analyzers, and modulated continuous-wave high-resolution near-infrared analyzers. A quantum cascade laser, for example, can emit coherent light in the mid-infrared region where NH 3 and other nitrogen compounds can effectively absorb the laser's energy. (c) Sampling system. Minimize NH 3 losses and sampling artifacts related to NH 3 adsorbing to surfaces by using sampling system components (sample lines, prefilters and valves) made of stainless steel or PTFE heated to (110 to 202) °C. If surface temperatures exceed ≥130 °C, take steps to prevent any DEF in the sample gas from thermally decomposing and hydrolyzing to form NH 3 . Use a sample line that is as short as practical. (d) Interference verification. Certain species can positively interfere with NDUV, FTIR, and laser infrared analyzers by causing a response similar to NH 3 . Perform interference verification as follows: (1) Perform SO 2 and H 2 O interference verification for NDUV analyzers using the procedures of § 1065.372, replacing occurances of NO X with NH 3 . NDUV analyzers must have combined interference that is within (0.0 ±2.0) µmol/mol. (2) Perform interference verification for FTIR and laser infrared analyzers using the procedures of § 1065.377. Use good engineering judgment to determine interference species. Note that interference species, with the exception of H 2 O, are dependent on the NH 3 infrared absorption band chosen by the instrument manufacturer. Determine interference species under this paragraph (d)(2) that are appropriate for each NH 3 infrared absorption band, or you may identify the interference species based on the instrument manufacturer's recommendations. [89 FR 29797, Apr. 22, 2024]
Cross-references to the CFR
1065.10101065.205.1065.2661065.307.1065.3721065.377.
40 C.F.R. § 1065.277: NH 3 measurement devices. | Justis AI