40 C.F.R. § 1065.659
Removed water correction.
Cite as 40 C.F.R. § 1065.659 (2026)
(a) If you remove water upstream of a concentration measurement, x , correct for the removed water. Perform this correction based on the amount of water at the concentration measurement, x H2O[emission]meas , and at the flow meter, x H2Oexh , whose flow is used to determine the mass emission rate or total mass over a test interval. For continuous analyzers downstream of a sample dryer for transient and ramped-modal cycles, you must apply this correction on a continuous basis over the test interval, even if you use one of the options in § 1065.145(e)(2) that results in a constant value for x H2O[emission]meas because x H2Oexh varies over the test interval. For batch analyzers, determine the flow-weighted average based on the continuous x H2Oexh values determined as described in paragraph (c) of this section. For batch analyzers, you may determine the flow-weighted average x H2Oexh based on a single value of x H2Oexh determined as described in paragraphs (c)(2) and (3) of this section, using flow-weighted average or batch concentration inputs. (b) Determine the amount of water remaining downstream of a sample dryer and at the concentration measurement using one of the methods described in § 1065.145(e)(2). If you use a sample dryer upstream of an analyzer and if the calculated amount of water remaining downstream of the sample dryer and at the concentration measurement, x H2O[emission]meas , is higher than the amount of water at the flow meter, x H2Oexh , set x H2O[emission]meas equal to x H2Oexh . If you use a sample dryer upstream of storage media, you must be able to demonstrate that the sample dryer is removing water continuously ( i.e., x H2Oexh is higher than x H2O[emission]meas throughout the test interval). (c) For a concentration measurement where you did not remove water, you may set x H2O[emission]meas equal to x H2Oexh . You may determine the amount of water at the flow meter, x H2Oexh , using any of the following methods: (1) Measure the dewpoint and absolute pressure and calculate the amount of water as described in § 1065.645. (2) If the measurement comes from raw exhaust, you may determine the amount of water based on intake-air humidity, plus a chemical balance of fuel, DEF, intake air, and exhaust as described in § 1065.655. (3) If the measurement comes from diluted exhaust, you may determine the amount of water based on intake-air humidity, dilution air humidity, and a chemical balance of fuel, DEF, intake air, and exhaust as described in § 1065.655. (d) Perform a removed water correction to the concentration measurement using the following equation: [73 FR 37335, June 30, 2008, as amended at 76 FR 57462, Sept. 15, 2011; 79 FR 23804, Apr. 28, 2014; 86 FR 34566, June 29, 2021]
- Cross-references to the CFR
- 1065.1451065.645.1065.655.