40 C.F.R. § 417.135

Standards of performance for new sources.

Last amended: 2016Year: 2026Length: 129 wordsOfficial source

Cite as 40 C.F.R. § 417.135 (2026)

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart; Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (kilograms per 1,000 kg of anhydrous product) BOD 5 0.30 0.15 COD 1.50 .75 TSS 0.04 .02 Surfactants 0.30 .15 Oil and grease 0.06 .03 pH ( 1 ) ( 1 ) English units (pounds per 1,000 lb of anhydrous product) BOD 5 0.30 0.15 COD 1.50 .75 TSS 0.04 .02 Surfactants 0.30 .15 Oil and grease 0.06 .03 pH ( 1 ) ( 1 ) 1 Within the range 6.0 to 9.0.
40 C.F.R. § 417.135: Standards of performance for new sources. | Justis AI