40 C.F.R. § 420.106
Pretreatment standards for new sources (PSNS).
Cite as 40 C.F.R. § 420.106 (2026)
Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources. (a) Cold rolling —(1) Recirculation—single stand. Subpart J Pollutant or pollutant property Pretreatment standards for new sources Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0.0000188 0.0000063 Zinc 0.0000063 0.0000021 Naphthalene 0.0000021 Tetrachloroethylene 0.0000031 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters. (2) Recirculation—multiple stands. Subpart J Pollutant or pollutant property Pretreatment standards for new sources Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 1 0.0000418 0.0000167 Lead 0.0000188 0.0000063 Nickel 1 0.0000376 0.0000125 Zinc 0.0000125 0.0000042 Naphthalene 0.0000042 Tetrachloroethylene 0.0000063 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters. (3) Combination. Subpart J Pollutant or pollutant property Pretreatment standards for new sources Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 1 0.000543 0.000217 Lead 0.000244 0.0000814 Nickel 1 0.000488 0.000163 Zinc 0.000163 0.0000542 Naphthalene 0.0000542 Tetrachloroethylene 0.0000813 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters. (4) Direct application—single stand. Subpart J Pollutant or pollutant property Pretreatment standards for new sources Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg pounds per 1,000 lb) of product Chromium 1 0.000104 0.0000418 Lead 0.0000469 0.0000156 Nickel 1 0.0000939 0.0000313 Zinc 0.0000313 0.0000104 Naphthalene 0.0000104 Tetrachloroethylene 0.0000156 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters. (5) Direct application—multiple stands. Subpart J Pollutant or pollutant property Pretreatment standards for new sources Maximum for any 1 day Average of daily values for 30 consecutive days Kg/kkg pounds per 1,000 lb) of product Chromium 1 0.00121 0.000484 Lead 0.000545 0.000182 Nickel 1 0.00109 0.000363 Zinc 0.000363 0.000121 Naphthalene 0.000121 Tetrachloroethylene 0.000182 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters. (b) Cold worked pipe and tube mills —(1) Using water. Subpart J Pollutant or pollutant property Pretreatment standards for new sources Maximum for any one day Average of daily values for 30 consecutive days kg/kkg (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0.0000188 0.0000063 Zinc 0.0000063 0.0000021 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewaters. (2) Using oil solutions. Subpart J Pollutant or pollutant property Pretreatment standards for new sources Maximum for any one day Average of daily values for 30 consecutive days kg/kkg (pound per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0.0000188 0.0000063 Zinc 0.0000063 0.0000021 Naphthalene 0.0000021 Tetrachloroethylene 0.0000031 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewasters. [47 FR 23284, May 27, 1982, as amended at 49 FR 21035, May 17, 1984]
- Cross-references to the CFR
- 40:403.7