40 C.F.R. § 444.13

Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).

Last amended: 2016Year: 2026Length: 87 wordsOfficial source

Cite as 40 C.F.R. § 444.13 (2026)

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BPT: Effluent Limitations 1 Regulated parameter Maximum daily Maximum monthly avg. TSS 113,000 34,800 Arsenic 84 72 Cadmium 71 26 Chromium 25 14 Copper 23 14 Lead 57 32 Mercury 2.3 1.3 Silver 13 8 Titanium 60 22 Zinc 82 54 pH ( 2 ) ( 2 ) 1 Micrograms per liter (ppb) 2 Within the range 6 to 9.
Cross-references to the CFR
40:125.30
40 C.F.R. § 444.13: Effluent limitations attainable by the application of the best practicable control technology currently available (BPT). | Justis AI