40 C.F.R. § 445.11
Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).
Cite as 40 C.F.R. § 445.11 (2026)
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations which represent the application of BPT: Effluent Limitations Regulated parameter Maximum daily 1 Maximum monthly avg. 1 BOD 5 220 56 TSS 88 27 Ammonia (as N) 10 4.9 α-Terpineol 0.042 0.019 Aniline 0.024 0.015 Benzoic acid 0.119 0.073 Naphthalene 0.059 0.022 p -Cresol 0.024 0.015 Phenol 0.048 0.029 Pyridine 0.072 0.025 Arsenic 1.1 0.54 Chromium 1.1 0.46 Zinc 0.535 0.296 pH ( 2 ) ( 2 ) 1 Milligrams per liter (mg/L, ppm). 2 Within the range 6 to 9. [65 FR 3048, Jan. 19, 2000; 65 FR 14344, Mar. 16, 2000]
- Cross-references to the CFR
- 40:125.30