40 C.F.R. § 465.34

Pretreatment standards for existing sources.

Last amended: 2016Year: 2026Length: 116 wordsOfficial source

Cite as 40 C.F.R. § 465.34 (2026)

Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources. The mass of wastewater pollutants in coil coating process wastewater introduced into a POTW shall not exceed the following values: Subpart C Pollutant or pollutant property PSES Maximum for any 1 day Maximum for monthly average mg/m 2 (pounds per 1 million ft 2 ) of area processed Chromium 0.42 (0.085) 0.17 (0.034) Cyanide 0.29 (0.059) 0.12 (0.024) Zinc 1.32 (0.27) 0.56 (0.12) [47 FR 54244, Dec. 1, 1982; 49 FR 33649, Aug. 24, 1984]
Cross-references to the CFR
40:403.7
40 C.F.R. § 465.34: Pretreatment standards for existing sources. | Justis AI