40 C.F.R. Table 1 to Subpart NNNa of Part 60

Table 1 to Subpart NNN a of Part 60—Emission Limits and Standards for Vent Streams

Last amended: 2024Year: 2026Length: 107 wordsOfficial source

Cite as 40 C.F.R. Table 1 to Subpart NNNa of Part 60 (2026)

For each . . . You must . . . 1. Vent stream a. Reduce emissions of TOC (minus methane and ethane) by 98 weight-percent, or to a TOC (minus methane and ethane) concentration of 20 ppmv on a dry basis corrected to 3 percent oxygen by venting emissions through a closed vent system to any combination of non-flare control devices and/or recovery system and meet the requirements specified in § 60.663a and § 60.670a; or b. Reduce emissions of TOC (minus methane and ethane) by venting emissions through a closed vent system to a flare and meet the requirements specified in § 60.669a and § 60.670a.
Cross-references to the CFR
60.663a60.669a60.670a60.670a.
40 C.F.R. Table 1 to Subpart NNNa of Part 60: Table 1 to Subpart NNN a of Part 60—Emission Limits and Standards for Vent Streams | Justis AI