40 C.F.R. § 63.1385

Test methods and procedures.

Last amended: 2017Year: 2026Length: 472 wordsSubsections: 1Official source

Cite as 40 C.F.R. § 63.1385 (2026)

(a) The owner or operator shall use the following methods to determine compliance with the applicable emission limits: (1) Method 1 (40 CFR part 60, appendix A) for the selection of the sampling port location and number of sampling ports; (2) Method 2 (40 CFR part 60, appendix A) for volumetric flow rate; (3) Method 3 or 3A (40 CFR part 60, appendix A) for O 2 and CO 2 for diluent measurements needed to correct the concentration measurements to a standard basis; (4) Method 4 (40 CFR part 60, appendix A) for moisture content of the stack gas; (5) Method 5 or Method 29 (40 CFR part 60, appendix A-3) for the concentration of total PM. When using Method 5, each run must consist of a minimum sample volume of 2 dry standard cubic meters (dscm). When using Method 29, each run must consist of a minimum sample volume of 3 dscm. When measuring PM concentration using either Method 5 or 29, the probe and filter holder heating system must be set to provide a gas temperature no greater than 120±14 °C (248±25 °F). (6) For measuring the concentration of formaldehyde, use one of the following test methods: (i) Method 318 (appendix A of this part). Each test run must consist of a minimum of 10 spectra. (ii) Method 316 (appendix A of this part). Each test run must consist of a minimum of 2 dry standard cubic meters (dscm) of sample volume. (7) Method contained in appendix A of this subpart for the determination of product LOI; (8) Method contained in appendix B of this subpart for the determination of the free-formaldehyde content of resin. The owner or operator shall use vendor specifications to determine the free-phenol content of resin. (9) Method contained in appendix C of this subpart for the determination of product density; (10) For measuring the concentration of phenol, use Method 318 (appendix A of this part). Each test run must consist of a minimum of 10 spectra. (11) For measuring the concentration of methanol, use one of the following test methods: (i) Method 318 (appendix A of this part). Each test run must consist of a minimum of 10 spectra. (ii) Method 308 (appendix A of this part). Each test run must consist of a minimum of 2 hours. (12) Method 29 (40 CFR part 60, appendix A-8) for the concentration of chromium compounds. Each test run must consist of a minimum sample volume of 3 dscm. (13) An alternative method, subject to approval by the Administrator. (b) Each performance test shall consist of 3 runs. The owner or operator shall use the average of the three runs in the applicable equation for determining compliance. [64 FR 31709, June 14, 1999, as amended at 80 FR 45335, July 29, 2015; 82 FR 60885, Dec. 26, 2017]
40 C.F.R. § 63.1385: Test methods and procedures. | Justis AI