40 C.F.R. § 63.5989

What are my alternatives for meeting the emission limitations for puncture sealant application affected sources?

Last amended: 2026Year: 2026Length: 216 wordsOfficial source

Cite as 40 C.F.R. § 63.5989 (2026)

You must use one of the compliance alternatives in paragraphs (a) through (d) of this section to meet the emission limitations in § 63.5988. (a) Overall control efficiency alternative. Use an emissions capture system and control device and demonstrate that the application booth emissions meet the emission limits in table 3 to this subpart, option 1a or 1b, and the control device and capture system meet the operating limits in table 4 to this subpart. (b) Permanent total enclosure and control device efficiency alternative. Use a permanent total enclosure that satisfies the Method 204 criteria in 40 CFR part 51, appendix M. Demonstrate that the control device meets the emission limits in table 3 to this subpart, option 1a or 1b. You must also show that the control device and capture system meet the operating limits in table 4 to this subpart. (c) Monthly average alternative, without using an add-on control device. Use puncture sealants in such a way that the monthly average HAP emissions do not exceed the emission limits in table 3 to this subpart, option 2. (d) Monthly average alternative, using an add-on control device. Use a control device to reduce HAP emissions so that monthly average HAP emissions do not exceed the emission limits in table 3 to this subpart, option 2.
Cross-references to the CFR
63.5988.