40 C.F.R. § 63.7912

What are my inspection and monitoring requirements for separators?

Last amended: 2020Year: 2026Length: 194 wordsSubsections: 1Official source

Cite as 40 C.F.R. § 63.7912 (2026)

(a) If you use a floating roof according to § 63.7910(b)(1), you must meet requirements in paragraphs (a)(1) and (2) of this section. (1) Measure the seal gaps at least annually according to the requirements in § 63.1047(b)(1). (2) Visually inspect the floating roof at least annually according to the requirements in § 63.1047(b)(2). (b) If you use a cover vented to a control device according to § 63.7910(b)(1) or (2), you must meet requirements in paragraphs (b)(1) and (2) of this section. (1) You must visually inspect the cover and its closure devices for defects according to the requirements in § 63.1047(c). (2) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you. (c) If you use a pressurized separator that operates as a closed system according to § 63.7910(b)(3), you must visually inspect each pressurized separator and closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.1045(b), with the exceptions specified in § 63.7910(b)(3). [68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41705, July 10, 2020]