40 C.F.R. § 65.82
Design requirements.
Cite as 40 C.F.R. § 65.82 (2026)
(a) The owner or operator shall equip each transfer rack with either one of the following equipment: (1) A closed vent system which routes the regulated material vapors to a control device as provided in § 65.83(a)(1) and (2). (2) Process piping which routes the regulated material vapors to a process or a fuel gas system as provided in § 65.83(a)(4), or to a vapor balance system as provided in § 65.83(a)(3). (b) Each closed vent system shall be designed to collect the regulated material displaced from tank trucks or railcars during loading and to route the collected regulated material to a control device as provided in § 65.83(a)(1) and (2). (c) Process piping shall be designed to collect the regulated material displaced from tank trucks or railcars during loading and to route the collected regulated material vapors to a process or a fuel gas system as provided in § 65.83(a)(4), or to a vapor balance system as provided in § 65.83(a)(3). (d) Each closed vent system shall meet the applicable requirements of § 65.143. (e) If the collected regulated material vapors are routed to a process or a fuel gas system as provided in § 65.83(a)(4), then each owner or operator shall meet the applicable requirements of § 65.142(c).
- Cross-references to the CFR
- 65.14265.143.65.83