40 C.F.R. § 76.5
NO X emission limitations for Group 1 boilers.
Cite as 40 C.F.R. § 76.5 (2026)
(a) Beginning January 1, 1996, or for a unit subject to section 404(d) of the Act, the date on which the unit is required to meet Acid Rain emission reduction requirements for SO 2 , the owner or operator of a Phase I coal-fired utility unit with a tangentially fired boiler or a dry bottom wall-fired boiler (other than units applying cell burner technology) shall not discharge, or allow to be discharged, emissions of NO X to the atmosphere in excess of the following limits, except as provided in paragraphs (c) or (e) of this section or in § 76.10, 76.11, or 76.12: (1) 0.45 lb/mmBtu of heat input on an annual average basis for tangentially fired boilers. (2) 0.50 lb/mmBtu of heat input on an annual average basis for dry bottom wall-fired boilers (other than units applying cell burner technology). (b) The owner or operator shall determine the annual average NO X emission rate, in lb/mmBtu, using the methods and procedures specified in part 75 of this chapter. (c) Unless the unit meets the early election requirement of § 76.8, the owner or operator of a coal-fired substitution unit with a tangentially fired boiler or a dry bottom wall-fired boiler (other than units applying cell burner technology) that satisfies the requirements of § 76.1(c)(2), shall comply with the NO X emission limitations that apply to Group 1, Phase II boilers. (d) The owner or operator of a Phase I unit with a cell burner boiler that converts to a conventional wall-fired boiler on or before January 1, 1995 or, for a unit subject to section 404(d) of the Act, the date the unit is required to meet Acid Rain emissions reduction requirements for SO 2 shall comply, by such respective date or January 1, 1996, whichever is later, with the NO X emissions limitation applicable to dry bottom wall-fired boilers under paragraph (a) of this section, except as provided in paragraphs (c) or (e) of this section or in § 76.10, 76.11, or 76.12. (e) The owner or operator of a Phase I unit with a Group 1 boiler that converts to a fluidized bed or other type of utility boiler not included in Group 1 boilers on or before January 1, 1995 or, for a unit subject to section 404(d) of the Act, the date the unit is required to meet Acid Rain emissions reduction requirements for SO 2 is exempt from the NO X emissions limitations specified in paragraph (a) of this section, but shall comply with the NO X emission limitations for Group 2 boilers under § 76.6. (f) Except as provided in § 76.8 and in paragraph (c) of this section, each unit subject to the requirements of this section is not subject to the requirements of § 76.7. [60 FR 18761, Apr. 13, 1995, as amended at 61 FR 67162, Dec. 19, 1996]
- Cross-references to the CFR
- 76.176.1076.6.76.7.76.8