46 C.F.R. § 111.107-1

Industrial systems.

Last amended: 2023Year: 2026Length: 223 wordsSubsections: 3Official source

Cite as 46 C.F.R. § 111.107-1 (2026)

(a) For the purpose of this subpart, an industrial system is a system that— (1) Is not a ship's service load, as defined in § 110.15-1; (2) Is used only for the industrial function of the vessel; (3) Is not connected to the emergency power source; and (4) Does not have specific requirements addressed elsewhere in this subchapter. (b) An industrial system that meets the applicable requirements of NFPA 70 (incorporated by reference; see § 110.10-1 of this subchapter) must meet only the following: (1) Part 110, subpart 110.25, of this chapter—Plan Submittal. (2) Subpart 111.01 of this part—General. (3) Subpart 111.05 of this part—Equipment Ground, Ground Detection, and Grounded Systems. (4) Sections 111.12-1(b) and 111.12-1(c)—Prime movers. (5) Sections 111.30-1, 111.30-5(a), and 111.30-19(a)—Switchgear. (6) Subpart 111.105 of this part—Hazardous Locations. (c) Cables that penetrate a watertight or fire boundary deck or bulkhead must— (1) Be installed in accordance with 46 CFR 111.60-5 and meet the flammability-test requirements of either IEEE 1202, IEC 60332-3-22:2018, or IEC 60332-3-21:2018, Category A or A F/R (all incorporated by reference; see § 110.10-1 of this subchapter); or (2) Be specialty cable installed in accordance with § 111.60-2. [CGD 94-108, 61 FR 28286, June 4, 1996, as amended at 62 FR 23910, May 1, 1997; USCG-2003-16630, 73 FR 65201, Oct. 31, 2008; USCG-2020-0075, 88 FR 16368, Mar. 16, 2023]
Cross-references to the CFR
110.10-1110.15-1111.60-2.46:111.60-5