46 C.F.R. § 112.43-15

Emergency lighting feeders.

Last amended: 2016Year: 2026Length: 68 wordsOfficial source

Cite as 46 C.F.R. § 112.43-15 (2026)

For a vessel with fire bulkheads forming fire zones, at least one emergency lighting feeder must supply only the emergency lights between two adjacent main vertical fire zone bulkheads. The emergency lighting feeder must be separated as widely as practicable from any general lighting feeder supplying the same space. [CGD 74-125A, 47 FR 15267, Apr. 8, 1982, as amended by CGD 94-108, 61 FR 28287, June 4, 1996]