46 C.F.R. § 116.600

Ventilation of enclosed and partially enclosed spaces.

Last amended: 2016Year: 2026Length: 120 wordsSubsections: 4Official source

Cite as 46 C.F.R. § 116.600 (2026)

(a) An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the space. (b) A power ventilation system must be capable of being shut down from the pilot house. (c) An enclosed passenger or crew accommodation space and any other space occupied by a crew member on a regular basis must be ventilated by a power ventilation system unless natural ventilation in all ordinary weather conditions is satisfactory to the OCMI. (d) An exhaust duct over a frying vat or a grill must be at least 11 U.S. Standard Gauge (USSG) steel. [CGD 85-080, 61 FR 900, Jan. 10, 1996, as amended at 62 FR 51350, Sept. 30, 1997]