46 C.F.R. § 118.310

Fire main and hydrants.

Last amended: 2016Year: 2026Length: 155 wordsSubsections: 5Official source

Cite as 46 C.F.R. § 118.310 (2026)

(a) Except as required by paragraph (d) of this section, a vessel must have a sufficient number of fire hydrants to reach any part of the vessel using a single length of firehose. (b) Piping, valves, and fittings in a fire main system must comply with part 119, subpart G of this subchapter. (c) Each fire hydrant must have a valve installed to allow the firehose to be removed while the fire main is under pressure. (d) On a vessel carrying more than 600 passengers or with overnight accommodations for more than 49 passengers, the fire main and hydrants must meet § 76.10-10 of this chapter. (e) Spanner wrenches must be provided for each fire hydrant required by this regulation. Existing vessels must comply with this requirement by January 18, 2017. [CGD 85-080, 61 FR 917, Jan. 10, 1996, as amended at 62 FR 51351, Sept. 30, 1997; USCG-2012-0196, 81 FR 48270, July 22, 2016]
Cross-references to the CFR
76.10-10
46 C.F.R. § 118.310: Fire main and hydrants. | Justis AI