46 C.F.R. § 119.470

Ventilation of spaces containing diesel fuel tanks.

Last amended: 2016Year: 2026Length: 103 wordsSubsections: 2Official source

Cite as 46 C.F.R. § 119.470 (2026)

(a) Unless provided with ventilation that complies with § 119.465 of this part, a space containing a diesel fuel tank and no machinery must meet one of the following requirements: (1) A space of 14 cubic meters (500 cubic feet) or more in volume must have a gooseneck vent of not less than 65 millimeters (2.5 inches) in diameter; or (2) A space of less than 14 cubic meters (500 cubic feet) in volume must have a gooseneck vent of not less than 40 millimeters (1.5 inches) in diameter. (b) Vent openings may not be located adjacent to possible sources of vapor ignition.
Cross-references to the CFR
119.465