46 C.F.R. § 131.585

Periodic servicing of hydrostatic-release units.

Last amended: 2016Year: 2026Length: 86 wordsSubsections: 2Official source

Cite as 46 C.F.R. § 131.585 (2026)

(a) Except a disposable hydrostatic-release unit with an expiration date, each hydrostatic-release unit must be serviced— (1) Within 12 months of its manufacture and within 12 months of each subsequent servicing, except when a servicing due after 12 months is delayed not more than 5 months until the next scheduled inspection of the vessel; and (2) In compliance with subpart 160.062 of this chapter. (b) The springs of each spring-tensioned gripe used with a hydrostatic-release unit must be renewed when the unit is serviced and tested.
46 C.F.R. § 131.585: Periodic servicing of hydrostatic-release units. | Justis AI