46 C.F.R. § 153.361

Arrangements for removal of valves from venting systems having multiple relief valves.

Last amended: 2016Year: 2026Length: 91 wordsSubsections: 2Official source

Cite as 46 C.F.R. § 153.361 (2026)

A venting system having multiple relief valves may be arranged to allow the removal of a valve (for repair, as an example) provided the venting system: (a) Has valves that are interlocked, so that the removal of a valve does not reduce the venting system relieving capacity below the minimum relieving capacity required by § 153.358; and (b) Is arranged so that cargo vapor will not escape through the opening left after a valve has been removed. [CGD 78-128, 47 FR 21208, May 17, 1982; 47 FR 27293, June 24, 1982]
Cross-references to the CFR
153.358
46 C.F.R. § 153.361: Arrangements for removal of valves from venting systems having multiple relief valves. | Justis AI