46 C.F.R. § 161.013-3

General performance requirements.

Last amended: 2016Year: 2026Length: 148 wordsSubsections: 2Official source

Cite as 46 C.F.R. § 161.013-3 (2026)

(a) Each electric light must: (1) Emit a white light which meets the intensity requirements of § 161.013-5; (2) Be capable of automatic signaling in a manner which meets the requirements of § 161.013-7; (3) Contain an independent power source which meets the requirements of § 161.013-9; (4) Float in fresh water with the lens surface at or above the surface of the water; (5) Be equipped with a waterproof switch; and (6) Meet the requirement of paragraphs (a) (1) through (4) of this section after floating for at least 72 hours followed by submersion in 5% by weight sodium chloride solution for at least 2 hours. (b) The electric light may not be equipped with a switch mechanism which permits continuous display of a beam of light except that the light may be equipped with a switch which returns to the off position when pressure is released.
Cross-references to the CFR
161.013-5161.013-7161.013-9