46 C.F.R. § 171.067

Treatment of stepped and recessed bulkheads in Type I subdivision.

Last amended: 2016Year: 2026Length: 370 wordsSubsections: 7Official source

Cite as 46 C.F.R. § 171.067 (2026)

(a) For the purpose of this section— (1) The main transverse watertight bulkhead immediately forward of a stepped bulkhead is referred to as bulkhead 1; and (2) The main transverse watertight bulkhead immediately aft of the stepped bulkhead is referred to as bulkhead 3. (b) If a main transverse watertight bulkhead is stepped, it and bulkheads 1 and 3 must meet one of the following conditions: (1) The separation between bulkheads 1 and 3 must not exceed the following: (i) If the factor of subdivision (FS) determined from § 171.065 (a) or (b) is greater than 0.9, the distance between bulkheads 1 and 3 must not exceed the maximum separation calculated to demonstrate compliance with § 171.065. (ii) If the factor of subdivision is 0.9 or less, the distance between bulkheads 1 and 3 must not exceed 90% of the floodable length or twice the maximum bulkhead separation calculated to demonstrate compliance with § 171.065, whichever is smaller. (2) Additional watertight bulkheads must be located as shown in Figure 171.067(a) so that distances A, B, C, and D, illustrated in Figure 171.067(a), satisfy the following: (i) Distances A and B must not exceed the maximum spacing allowed by § 171.065. (ii) Distances C and D must not be less than the minimum separation prescribed by § 171.065(e). (3) The distance A, illustrated in Figure 171.067(b), must not exceed the maximum length determined in § 171.065 corresponding to a margin line taken 3 inches (7.6 cm) below the step. (c) A main transverse bulkhead may not be recessed unless all parts of the recess are inboard from the shell of the vessel a distance A as illustrated in Figure 171.067(c). (d) Any part of a recess that lies outside the limits defined in paragraph (c) of this section must be treated as a step in accordance with paragraph (b) of this section. (e) The distance between a main transverse watertight bulkhead and the transverse plane passing through the nearest portion of a recessed bulkhead must be greater than the minimum separation specified by § 171.065(e). (f) If a main transverse bulkhead is stepped or recessed, equivalent plane bulkheads must be used in the calculations required to demonstrate compliance with § 171.065.
Cross-references to the CFR
171.065171.065.
46 C.F.R. § 171.067: Treatment of stepped and recessed bulkheads in Type I subdivision. | Justis AI