46 C.F.R. § 181.310

Fire main and hydrants.

Last amended: 2016Year: 2026Length: 132 wordsSubsections: 4Official source

Cite as 46 C.F.R. § 181.310 (2026)

(a) A vessel that has a power driven fire pump must have a sufficient number of fire hydrants to reach any part of the vessel using a single length of firehose. (b) Piping, valves, and fittings in a fire main system must comply with subpart G, part 182, of this chapter. (c) Each fire hydrant must have a valve installed to allow the firehose to be removed while the fire main is under pressure. (d) Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Existing vessels as of July 22, 2016 have 180 days to comply with this requirement. [CGD 85-080, 61 FR 982, Jan. 10, 1996, as amended at 62 FR 51358, Sept. 30, 1997; USCG-2012-0196, 81 FR 48299, July 22, 2016]
Cross-references to the CFR
181.320