46 C.F.R. § 32.56-22

Openings in and insulation of boundaries: Other spaces—T/ALL.

Last amended: 2016Year: 2026Length: 92 wordsSubsections: 2Official source

Cite as 46 C.F.R. § 32.56-22 (2026)

If openings are fitted into the following exterior boundaries of any space other than an accommodation, service, or control space, the interior of the space must be insulated to “A-60” Class and the space must not provide access to any accommodation, service, or control space: (a) The exterior boundaries that face the cargo area. (b) The portion of the exterior boundaries within 3 meters (10 feet) or the length of the vessel divided by 25, whichever is greater, except that the distance need not exceed 5 meters (16.4 feet), of these boundaries.