46 C.F.R. § 52.01-10

Automatic controls.

Last amended: 2024Year: 2026Length: 106 wordsSubsections: 3Official source

Cite as 46 C.F.R. § 52.01-10 (2026)

(a) Each main boiler must meet the special requirements for automatic safety controls in § 62.35-20(a)(1) of this subchapter. (b) Each automatically controlled auxiliary boiler having a heat input rating of less than 12,500,000 Btu/hr. (3.66 megawatts) must meet the requirements of part 63 of this subchapter. (c) Each automatically controlled auxiliary boiler with a heat input rating of 12,500,000 Btu/hr. (3.66 megawatts) or above, must meet the requirements for automatic safety controls in part 62 of this subchapter. [CGFR 68-82, 33 FR 18815, Dec. 18, 1968, as amended by CGD 81-030, 53 FR 17837, May 18, 1988; CGD 88-057, 55 FR 24236, June 15, 1990]