46 C.F.R. § 58.30-50

Requirements for miscellaneous fluid power and control systems.

Last amended: 2024Year: 2026Length: 114 wordsSubsections: 2Official source

Cite as 46 C.F.R. § 58.30-50 (2026)

(a) All fluid power and control systems installed on a vessel, except those listed in § 58.30-1(a), must meet the following requirements: (1) Diagrams of the system providing the information required by § 58.30-40(a)(1) through (4) must be submitted. These are not approved but are needed for records and for evaluation of the system in accordance with § 58.30-1(a)(14). (2) The hydraulic fluid used in the system must comply with § 58.30-10. (3) The installed system must be tested in accordance with § 58.30-35(c)(2). (4) All pneumatic cylinders must comply with § 58.30-30. (5) Additional plans may be required for “fail-safe” equipment and for cargo hatch systems with alternate means of operation. (b) [Reserved]
Cross-references to the CFR
58.30-158.30-10.58.30-30.58.30-3558.30-40