46 C.F.R. § 76.01-5

Equipment installed but not required.

Last amended: 2016Year: 2026Length: 124 wordsSubsections: 2Official source

Cite as 46 C.F.R. § 76.01-5 (2026)

(a) Where extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation must meet the requirements of this part. (b) Use of non-approved fire detection systems may be acceptable as excess equipment provided that: (1) Components are listed by a nationally recognized testing laboratory (NRTL) as that term is defined in 46 CFR 161.002-2, and are designed, installed, tested, and maintained in accordance with an appropriate industry standard and the manufacturer's specific guidance; (2) Installation conforms to the requirements of 46 CFR chapter I, subchapter J (Electrical Engineering), especially the hazardous location electrical installation regulations in 46 CFR 111.105; and (3) Coast Guard plan review is completed for wiring plans. [USCG-2012-0196, 81 FR 48252, July 22, 2016]
Cross-references to the CFR
46:111.10546:161.002-2