47 C.F.R. § 22.659
Effective radiated power limits.
Cite as 47 C.F.R. § 22.659 (2026)
The purpose of the rules in this section, which limit effective radiated power (ERP), is to reduce the likelihood that interference to television reception from public mobile operations on these channels will occur. The protected TV station locations specified in this section are the locations of record as of September 1974, and these do not change even though the TV stations may have been subsequently relocated.
(a)
Maximum ERP.
The ERP of base transmitters must not exceed 100 Watts under any circumstances. The ERP of mobile transmitters must not exceed 60 Watts under any circumstances.
(b)
Co-channel protection from base transmitters.
The ERP of base transmitters in the New York-Northeastern New Jersey urban area must not exceed the limits in the tables referenced in paragraphs (b)(2) and (b)(3) of this section. The limits depend upon the height above average terrain of the base transmitter antenna and the distance between the base transmitter and the nearest protected TV station location in paragraph (b)(1) of this section.
(1) The protected TV station locations are as follows (all coordinates are referenced to North American Datum 1983 (NAD83)):
Control transmitter frequency range
Protected TV station location
470-476 MHz
Washington, DC, 38°57′17.4″ N. Lat. 77°00′15.9″ W. Long.
476-482 MHz
Lancaster, PA, 40°15′45.3″ N. Lat. 76°27′47.9″ W. Long.
(2) Tables E-8 and E-9 of this section apply to base transmitters in the New York-Northeastern New Jersey urban area that transmit on channels in the 476-482 MHz range.
(3) Tables E-10 and E-11 of this section apply to base transmitters in the New York-Northeastern New Jersey urban area that transmit on channels in the 470-476 MHz range.
(c)
Adjacent channel protection from base transmitters.
The ERP of base transmitters must not exceed the limits in Table E-12 of this section. The limits depend upon the height above average terrain of the base transmitter antenna and the distance between the base transmitter and the nearest protected TV station location specified in paragraph (c)(1) of this section.
(1) The protected TV station locations are as follows (all coordinates are referenced to North American Datum 1983 (NAD83)):
Control transmitter frequency range
Protected TV station location
TV channel
470-476 MHz
Hanover, NH, 43°42′30.3″ N. Lat. 72°09′14.3″ W. Long
(15)
476-482 MHz
482-488 MHz
Lancaster, PA, 40°15′45.3″ N. Lat. 76°27′47.9″ W. Long
(15)
Scranton, PA, 41°10′58.3″ N. Lat. 75°52′19.7″ W. Long
(16)
Hanover, NH, 43°42′30.3″ N. Lat. 72°09′14.3″ W. Long
(15)
Note:
Coordinates are referenced to North American Datum 1983 (NAD83).
(2) Table E-12 of this section applies to base transmitters in the New York-Northeastern New Jersey urban area.
Table E-8—Maximum ERP (Watts) for Base Transmitters (HAAT 152 Meters or Less)
Distance to protected TV station in kilometers (miles)
Antenna height above average terrain in meters (feet)
15
(50)
30
(100)
46
(150)
61
(200)
76
(250)
91
(300)
107
(350)
122
(400)
137
(450)
152
(500)
209 (130)
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
201 (125)
1000
1000
1000
1000
1000
1000
1000
850
750
725
193 (120)
1000
1000
1000
1000
900
750
675
600
550
500
185 (115)
1000
1000
800
725
600
525
475
425
375
350
177 (110)
850
700
600
500
425
375
325
300
275
225
169 (105)
600
475
400
325
275
250
225
200
175
150
161 (100)
400
325
275
225
175
150
140
125
110
100
153 (95)
275
225
175
125
110
95
80
70
60
50
145 (90)
175
125
100
75
50
See § 22.659(b)(2). This table is for antenna heights of 152 meters (500 feet) or less above average terrain. For antenna heights between those in the table, use the next higher antenna height. For distances between those in the table, use the next lower distance.
Table E-9—Maximum ERP (Watts) for Base Transmitters (HAAT More Than 152 Meters)
Distance to protected TV station in kilometers (miles)
Antenna height above average terrain in meters (feet)
152 (500)
305 (1000)
457 (1500)
610 (2000)
762 (2500)
914 (3000)
209 (130)
1000
447
219
117
71
46
193 (120)
500
209
95
50
30
19
177 (110)
225
91
35
19
11
8
161 (100)
100
30
10
5
3
2
153 (95)
50
13
5
3
2
1
See § 22.659(b)(2). This table is for antenna heights of more than 152 meters (500 feet) above average terrain. For intermediate values of height and/or distance, use linear interpolation to obtain the maximum permitted ERP.
Table E-10—Maximum ERP (Watts) for Base Transmitters (HAAT 152 Meters or Less)
Distance to protected TV station in kilometers (miles)
Antenna height above average terrain in meters (feet)
15
(50)
30
(100)
46
(150)
61
(200)
76
(250)
91
(300)
107
(350)
122
(400)
137
(450)
152
(500)
261 (162)
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
257 (160)
1000
1000
1000
1000
1000
1000
1000
1000
1000
800
249 (155)
1000
1000
1000
1000
1000
875
775
700
625
575
241 (150)
1000
1000
950
775
725
625
550
500
450
400
233 (145)
850
750
650
575
500
440
400
350
320
300
225 (140)
600
575
465
400
350
300
275
250
230
225
217 (135)
450
400
335
300
255
240
200
185
165
150
209 (130)
350
300
245
200
185
160
145
125
120
100
201 (125)
225
200
170
150
125
110
100
90
80
75
193 (120)
175
150
125
105
90
80
70
60
55
50
See § 22.659(b)(3). This table applies for antenna heights of 152 meters (500 feet) or less above average terrain. For antenna heights between those in the table, use the next higher antenna height. For distances between those in the table, use the next lower distance.
Table E-11—Maximum ERP (Watts) for Base Transmitters (HAAT More Than 152 Meters)
Distance to protected TV station in kilometers (miles)
Antenna height above average terrain in meters (feet)
152 (500)
305 (1000)
457 (1500)
610 (2000)
762 (2500)
914 (3000)
261 (162)
1000
501
282
170
110
71
241 (150)
400
209
110
60
36
23
225 (140)
225
102
50
28
16
10
209 (130)
100
48
21
11
7
5
193 (120)
50
19
9
5
3
2
See § 22.659(b)(3). This table is for antenna heights of more than 152 meters (500 feet) above average terrain. For intermediate values of height and/or distance, use linear interpolation to obtain the maximum permitted ERP.
Table E-12—Maximum ERP (Watts) for Base Transmitters
Distance to protected TV station in kilometers (miles)
Antenna height above average terrain in meters (feet)
30
(100)
46
(150)
61
(200)
76
(250)
91
(300)
107
(350)
122
(400)
137
(450)
152
(500)
108 (67)
1000
1000
1000
1000
1000
1000
1000
1000
1000
106 (66)
1000
1000
1000
1000
1000
1000
1000
1000
750
105 (65)
1000
1000
1000
1000
1000
1000
825
650
600
103 (64)
1000
1000
1000
1000
1000
775
625
500
400
101 (63)
1000
1000
1000
1000
440
400
350
320
300
100 (62)
1000
1000
1000
525
375
250
200
150
125
98 (61)
1000
700
450
250
200
125
100
75
50
97 (60)
1000
425
225
125
100
75
50
See § 22.659(c)(2). This table applies to base transmitters in the New York-Northeastern New Jersey urban areas. This table is for antenna heights of 152 meters (500 feet) or less above average terrain. For antenna heights between those in the table, use the next higher antenna height. For distances between those in the table, use the next lower distance.
[59 FR 59507, Nov. 17, 1994, as amended at 63 FR 68947, Dec. 14, 1998]
- Cross-references to the CFR
- 22.659