47 C.F.R. § 90.221
Adjacent channel power limits.
Cite as 47 C.F.R. § 90.221 (2026)
(a) For the frequency bands indicated below, operations using equipment designed to operate with a 25 kHz channel bandwidth may be authorized up to a 22 kHz bandwidth if the equipment meets the adjacent channel power (ACP) limits below. The table specifies a value for the ACP as a function of the displacement from the channel center frequency and a measurement bandwidth of 18 kHz. (b)(1) Maximum adjacent power levels for frequencies in the 450-470 MHz band: Frequency offset Maximum ACP (dBc) for devices 1 watt and less Maximum ACP (dBc) for devices above 1 watt 25 kHz −55 dBc −60 dBc 50 kHz −70 dBc −70 dBc 75 kHz −70 dBc −70 dBc (2) In any case, no requirement in excess of −36 dBm shall apply. (c)(1) Maximum adjacent power levels for frequencies in the 809-824/854-869 MHz band: Frequency offset Maximum ACP (dBc) for devices less than 15 watts Maximum ACP (dBc) for devices 15 watts and above 25 kHz −55 dBc −55 dBc 50 kHz −65 dBc −65 dBc 75 kHz −65 dBc −70 dBc (2) In any case, no requirement in excess of −36 dBm shall apply. (d) On any frequency removed from the assigned frequency by more than 75 kHz, the attenuation of any emission must be at least 43 + 10 log (P watts ) dB. [77 FR 61538, Oct. 10, 2012]