49 C.F.R. § 192.113
Longitudinal joint factor (E) for steel pipe.
Cite as 49 C.F.R. § 192.113 (2026)
(a) The longitudinal joint factor to be used in the design formula in § 192.105 is determined in accordance with the table 1 to this paragraph (a):
Table 1 to Paragraph (
a
)
Specification
Pipe class
Longitudinal
joint factor
(E)
ASTM A53/A53M (incorporated by reference, see § 192.7)
Seamless
1.00
Electric resistance welded
1.00
Furnace butt welded
.60
ASTM A106/A106M (incorporated by reference, see § 192.7)
Seamless
1.00
ASTM A333/A333M (incorporated by reference, see § 192.7)
Seamless
1.00
Electric resistance welded
1.00
ASTM A381 (incorporated by reference, see § 192.7)
Double submerged arc welded
1.00
ASTM A671/A671M (incorporated by reference, see § 192.7)
Electric-fusion-welded
1.00
ASTM A672/A672M (incorporated by reference, see § 192.7)
Electric-fusion-welded
1.00
ASTM A691/A691M (incorporated by reference, see § 192.7)
Electric-fusion-welded
1.00
API Spec 5L (incorporated by reference, see § 192.7)
Seamless
1.00
Electric resistance welded
1.00
Electric flash welded
1.00
Submerged arc welded
1.00
Furnace butt welded
.60
Other
Pipe over 4 inches (102 millimeters)
.80
Other
Pipe 4 inches (102 millimeters) or less
.60
(b) If the type of longitudinal joint cannot be determined, the joint factor to be used must not exceed that designated for “Other.”
[Amdt. 192-135, 89 FR 33280, Apr. 29, 2024, as amended by Amdt. 192-156, 90 FR 40763, Aug. 21, 2025]
- Cross-references to the CFR