49 C.F.R. § 236.339
Mechanical locking, maintenance requirements.
Cite as 49 C.F.R. § 236.339 (2026)
Locking and connections shall be maintained so that, when a lever or latch is mechanically locked the following will be prevented:
(a)
Mechanical machine
—(1)
Latch-operated locking.
Raising lever latch block so that bottom thereof is within three-eighths inch of top of quadrant.
(2)
Lever-operated locking.
Moving lever latch block more than three-eighths inch on top of quadrant.
(b)
Electromechanical machine
—(1)
Lever moving in horizontal plant.
Moving lever more than five-sixteenths inch when in normal position or more than nine-sixteenths inch when in reverse position.
(2)
Lever moving in arc.
Moving lever more than 5 degrees.
(c)
Power machine
—(1)
Latch-operated locking.
Raising lever latch block to that bottom thereof is within seven thirty-seconds inch of top of quadrant.
(2)
Lever moving in horizontal plane.
Moving lever more than five-sixteenths inch when in normal position or more than nine-sixteenths inch when in reverse position.
(3)
Lever moving in arc.
Moving lever more than 5 degrees.