10 C.F.R. Appendix B to Subpart C of Part 429

Sampling Plan for Enforcement Testing of Covered Equipment and Certain Low-Volume Covered Products

Last amended: 2016Year: 2026Length: 274 wordsOfficial source

Cite as 10 C.F.R. Appendix B to Subpart C of Part 429 (2026)

The Department will determine compliance as follows: (a) The first sample size (n 1 ) must be four or more units, except as provided by § 429.57(e)(1)(ii). (b) Compute the mean of the measured energy performance (x 1 ) for all tests as follows: where x i is the measured energy efficiency or consumption from test i, and n 1 is the total number of tests. (c) Compute the standard deviation (s 1 ) of the measured energy performance from the n 1 tests as follows: (d) Compute the standard error (s x1 ) of the measured energy performance from the n 1 tests as follows: (e)(1) For an energy efficiency standard (EES), determine the appropriate lower control limit (LCL 1 ) according to: And use whichever is greater. Where EES is the energy efficiency standard and t is a statistic based on a 97.5 percent, one-sided confidence limit and a sample size of n 1 . (2) For an energy consumption standard (ECS), determine the appropriate upper control limit (UCL 1 ) according to: And use whichever is less, where ECS is the energy consumption standard and t is a statistic based on a 97.5 percent, one-sided confidence limit and a sample size of n 1 . (f)(1) Compare the sample mean to the control limit. (i) The basic model is in compliance and testing is at an end if: (A) For an energy or water efficiency standard, the sample mean is equal to or greater than the lower control limit, or (B) For an energy or water consumption standard, the sample mean is equal to or less than the upper control limit.
Cross-references to the CFR
429.57
10 C.F.R. Appendix B to Subpart C of Part 429: Sampling Plan for Enforcement Testing of Covered Equipment and Certain Low-Volume Covered Products | Justis AI