64E-5.1304, F.A.C.

64E-5.1304. Inventory Requirements

Last amended: 1993Year: 2026Length: 85 wordsOfficial source

Cite as Fla. Admin. Code r. 64E-5.1304

A licensee who possesses sealed sources shall conduct a physical inventory of all such sealed sources semiannually unless another interval is specified in the license. Inventory records shall be retained for 3 years. Inventory records shall contain the following: (1) The model and serial number of each sealed source; (2) The identity of each sealed source radionuclide and its estimated activity; (3) The location of each sealed source; (4) The date of the inventory; and, (5) The signature of the radiation safety officer or designee.
64E-5.1304, F.A.C.: 64E-5.1304. Inventory Requirements | Justis AI