HAR §4-44-18
HAR §4-44-18. Penalties
Cite as Haw. Code R. § 4-44-18
Any person who violates any
provision of this chapter may be subject to the
actions, procedures, and penalties provided in sections
147-25 and 147-63, Hawaii Revised Statutes. [Eff
1/16/84; ren and comp 3/24/86] (Auth: HRS ''147-22
and 147-63) (Imp: HRS ''147-25 and 147-63)
44-54
4-44-
FIGURE 1
CAPILLARY CPC VISCOMETER
8/24/68
44-55
TABLE I 1/
Approximate Revolutions of Centrifuge Machine-8/24/68
Approximate
Diameter 2/
Revolutions Per Min.
(A)
(B)
10 inches .............. 1,609
2,577
10-1/2 inches .............. 1,570
2,515
11 inches .............. 1,534
2,457
11-1/2 inches .............. 1,500
2,403
12 inches .............. 1,468
2,353
12-1/2 inches .............. 1,438
2,305
13 inches .............. 1,410
2,260
13-1/2 inches .............. 1,384
2,218
14 inches .............. 1,359
2,178
14-1/2 inches .............. 1,336
2,140
15 inches .............. 1,313
2,104
15-1/2 inches .............. 1,292
2,070
l6 inches .............. 1,271
2,037
16-1/2 inches .............. 1,252
2,006
l7 inches .............. 1,234
1,977
17-1/2 inches .............. 1,216
1,948
18 inches .............. 1,199
1,921
18-1/2 inches .............. 1,182
1,895
19 inches .............. 1,167
1,870
19-1/2 inches .............. 1,152
1,846
20 inches .............. 1,137
1,822
20-1/2 inches .............. 1,125
1,800
1/
This table, calculated from the formula R.C.F. =
0.00001118 N2r provides a Relative Centrifugal
Force of 364.6 times gravity for (A) and 942 times
gravity for (B).
R.C.F. = Relative centrifugal force (gravities)
r = Rotating radius (centimeters)
N = Rotating speed (rev. per min.)
2/
The distance between the tips of opposing
centrifuge tubes in operating position.