HAR §11-39-17

HAR §11-39-17. Severability

Last amended: 1983Length: 968 wordsOfficial source

Cite as Haw. Code R. § 11-39-17

If any provision of this chapter, or the application thereof to any person or circumstance is held invalid, the invalidity does not affect other provisions or applications of the chapter which can be given effect without the invalid provision or application, and to this end the provisions of this chapter are severable. [Eff. January 31, 1983] (Auth: HRS §§321-9, 321-11) (Imp: HRS §§321-1, 321-11) 39-10 The Department of Health authorized the repeal of Chapter 28, Public Health Regulations and the adoption of Chapter 39 of Title 11, Administrative Rules on January 3, 1983 following public hearing held on Oahu on August 26, 1982 and October 6, 1982, on Hawaii on August 25, 1982 and October 14, 1982, on Kauai on August 31, 1982 and October 19, 1982, on Maui on August 24, 1982 and October 13, 1982 after public notice was given in the Honolulu Star-Bulletin on August 3, 1982 and September 11, 1982, in the Hawaii Tribune-Herald on August 3, 1982 and September 14, 1982, in the Garden Isle on August 3, 1982 and September 13, 1982, and in the Maui News on August 3, 1982 and September 13, 1982. Chapter 39 of Title 11, Administrative Rules and the repeal of Chapter 28, Public Health Regulations shall take effect ten days after filing with the Office of the Lieutenant Governor. Charles G. Clark CHARLES G. CLARK Director Department of Health APPROVED: George R. Ariyoshi GEORGE R. ARIYOSHI GOVERNOR STATE OF HAWAII Dated: 1-19-83 APPROVED AS TO FORM: Jay W. Nelson Filed: January 20, 1983 Effective Date: January 31, 1983 FORM 1 DEPARTMENT OF HEALTH STATE OF HAWAII BOISE & RADIATION BRANCH ENVIRONMENTAL PROTECTION & HEALTH SERVICES DIVISION # APPLICATION FOR PERMIT ☐ Air Conditioning ☐ Ventilation (Submit an original and a duplicate with one set of plans. One copy will be returned after review if permit is granted.) I hereby apply for a permit on the project described below and enclose plans which were prepared by me or under my direct supervision. I certify that to the best of my knowledge the design is in complete accordance with the Air Conditioning and Ventilation Regulations of the Department of Health. (Except as noted under "Remarks.") | FIRM & ENGINEER | | | PROJECT | | | | | --- | --- | --- | --- | --- | --- | --- | | Firm: Engineer's Name: Address: City: Zip: Phone: | | | Name: Address: City: Zip: | | | | | Type of Occupancy | | | Design Out: DB WB Conditions In: DB % RH | | | | | Unit or Zone No.* | | | | | | Project Total | | Area Served (Name) | | | | | | | | Conditioned Area, Sq. Ft. | | | | | | | | Persons Occupying | | | | | | | | Outdoor Air, CFM | | | | | | | | Supply Air, CFM | | | | | | | | Zone Total Heat, BTUH | | | | | | | | Unusual Heat, BTUH | | | | | | | | Equipment Capacity, Tons | | | | | | | | Exhaust: CFM | | | | | | | | : Location | | | | | | | | Remarks: | | | | | | | | DEPARTMENT OF HEALTH SECTION | | | | ENGINEER'S CERTIFICATION | | | | Permit for installation, alteration or operation is granted in accordance with this application and its accompanying plans. This permit is revocable for cause. Within 60 days after completion of the system, the applicant shall notify the Department of Health in writing that the system is installed and operating substantially as designed. Signature: Name: Title: | | | | Signature: Date: Engineer's seal shall be affixed | | | | PERMIT NO. | Date: | | | | | | | Remarks: | | | | | | | *Attach additional pages if more data required. ![img-1.jpeg](img-1.jpeg) HOOD AGAINST WALL Q = 80 cfm/sq ft of hood area (80 WL) Not less than 50 cfm/sq ft of face area (50 PH) Duct velocity = 1000-4000 fpm, to suit conditions Entry loss = (filter resistance + 0.1") + 0.50 VP (straight take off) Entry loss = (filter resistance + 0.1") + 0.25 VP (tapered take off) P=perimeter of hood = 2W+L ![img-2.jpeg](img-2.jpeg) ISLAND TYPE HOOD Q = 125 cfm/sq ft of hood area (125 WL) Not less than 50 cfm/sq ft of face area (50 PH) Duct velocity = 1000-4000 fpm, to suit conditions Entry loss = (filter resistance + 0.1") + 0.50 VP (straight take off) Entry loss = (filter resistance + 0.1") + 0.25 VP (tapered take off) P=perimeter of hood = 2W+2L Note: See VS-911 for information about filters and fans KITCHEN RANGE HOODS Figure 1 ![img-3.jpeg](img-3.jpeg) 0=200 cfm/lineal ft of cooking surface (200L) Duct velocity = 1000-4000 fpm, to suit conditions Entry loss=(filter resistance+0.1")+0.5VP(straight take off) Entry loss=(filter resistance+0.1")+0.25 VP(tapered take off) # NOTES FOR KITCHEN HOODS # Filters: 1. Select practical filter size. 2. Determine number of filters required from manufacturer's data. (Usually: 2 cfm maximum exhaust for each sq in of filter area) 3. Install at 45°-60° to horizontal. Never horizontal. 4. Filter mounting height (Reference 65) a. No exposed cooking flame—1½ minimum to lowest edge of filter. b. Charcoal and similar fires—4 minimum to lowest edge of filter. 5. Shield filters from direct radiant heat. 6. Provide removable grease drip pan. 7. Clean pan and filters regularly. # Fan: 1. Use upblast discharge fan. Downblast is not recommended. 2. Select fan for design Q and SP resistance of filters and ductwork. 3. Adjust fan specification for expected exhaust air temperature. KITCHEN RANGE HOOD Figure 2
HAR §11-39-17: HAR §11-39-17. Severability | Justis AI