HAR §11-45-59
HAR §11-45-59. Use of other controls
Cite as Haw. Code R. § 11-45-59
When it is not
practicable to apply process or other engineering controls to
control the concentrations of radioactive material in air to
values below those that define an airborne radioactivity area, the
licensee shall, consistent with maintaining the total effective
dose equivalent ALARA, increase monitoring and limit intakes by
one or more of the following means:
(1)
Control of access; or
(2)
Limitation of exposure times; or
(3)
Use of respiratory protection equipment; or
(4)
Other controls. [Eff 11/12/99] (Auth: HRS §§321-10,
321-11, 321-71) (Imp: HRS §§321-1, 321-11(21), 321-
71)
§11-45-60 Use of individual respiratory protection
equipment. (a) If the licensee uses respiratory protection
equipment to limit intakes pursuant to section 11-45-59:
(1)
Except as provided in paragraph (2), the licensee
shall use only respiratory protection equipment that
is tested and certified or had certification extended
by the National Institute for Occupational Safety and
Health and the Mine Safety and Health Administration.
(2)
If the licensee wishes to use equipment that has not
been tested or certified by the National Institute for
Occupational Safety and Health and the Mine Safety and
Health Administration, and has not had certification
extended by the National Institute for Occupational
Safety and Health and the Mine Safety and Health
Administration, or for which there is no schedule for
testing or certification, the licensee shall submit an
application for authorized use of that equipment,
§11-45-60
45-66
including a demonstration by testing, or a
demonstration on the basis of reliable test
information, that the material and performance
characteristics of the equipment are capable of
providing the proposed degree of protection under
anticipated conditions of use.
(3)
The licensee shall implement and maintain a
respiratory protection program that includes:
(A)
Air sampling sufficient to identify the
potential hazard, permit proper equipment
selection, and estimate exposures; and
(B)
Surveys and bioassays, as appropriate, to
evaluate actual intakes; and
(C)
Testing of respirators for operability
immediately before each use; and
(D)
Written procedures regarding selection, fitting,
issuance, maintenance, and testing of
respirators, including testing for operability
immediately before each use; supervision and
training of personnel; monitoring, including air
sampling and bioassays; and recordkeeping; and
(E)
Determination by a physician before initial
fitting of respirators, and at least every
twelve months thereafter, that the individual
user is physically able to use the respiratory
protection equipment.
(4)
The licensee shall issue a written policy statement on
respirator usage covering:
(A)
The use of process or other engineering
controls, instead of respirators; and
(B)
The routine, nonroutine, and emergency use of
respirators; and
(C)
The length of periods of respirator use and
relief from respirator use.
(5)
The licensee shall advise each respirator user that
the user may leave the area at any time for relief
from respirator use in the event of equipment
malfunction, physical or psychological distress,
procedural or communication failure, significant
deterioration of operating conditions, or any other
conditions that might require such relief.
(6)
The licensee shall use equipment within the equipment
manufacturer's expressed limitations for type and mode
of use and shall provide proper visual, communication,
and other special capabilities, such as adequate skin
protection, when needed.
(b)
When estimating exposure of individuals to airborne
radioactive materials, the licensee may make allowance for
respiratory protection equipment used to limit intakes pursuant to
section 11-45-59, provided that the following conditions, in
addition to those in subsection (a), are satisfied:
(1)
The licensee selects respiratory protection equipment
that provides a protection factor, specified in
Appendix A, greater than the multiple by which peak
§11-45-61
45-67
concentrations of airborne radioactive materials in
the working area are expected to exceed the values
specified in Appendix B, Table I, Column 3. However,
if the selection of respiratory protection equipment
with a protection factor greater than the peak
concentration is inconsistent with the goal specified
in section 11-45-59 of keeping the total effective
dose equivalent ALARA, the licensee may select
respiratory protection equipment with a lower
protection factor provided that such a selection would
result in a total effective dose equivalent that is
ALARA. The concentration of radioactive material in
the air that is inhaled when respirators are worn may
be initially estimated by dividing the average
concentration in air, during each period of
uninterrupted use, by the protection factor. If the
exposure is later found to be greater than initially
estimated, the corrected value shall be used; if the
exposure is later found to be less than initially
estimated, the corrected value may be used.
(2)
The licensee shall obtain authorization from the
department before assigning respiratory protection
factors in excess of those specified in Appendix A.
The department may authorize a licensee to use higher
protection factors on receipt of an application that:
(A)
Describes the situation for which a need exists
for higher protection factors, and
(B)
Demonstrates that the respiratory protection
equipment provides these higher protection
factors under the proposed conditions of use.
(c)
In an emergency, the licensee shall use as emergency
equipment only respiratory protection equipment that has been
specifically certified or had certification extended for emergency
use by the National Institute for Occupational Safety and Health
and the Mine Safety and Health Administration.
(d)
The licensee shall notify the department in writing at
least thirty days before the date that respiratory protection
equipment is first used pursuant to either subsection (a) or (b).
(e)
The exhibit at the end of chapter 11-45 entitled,
"Appendix A of Subchapter 4, Protection Factors for Respirators
(2/2/93)", is made a part of this section.
(f)
Appendix B to Part D of the Conference of Radiation
Control Program Directors, Inc. Suggested State Regulations for
Control of Radiation, Volume I, December 1995 Edition, entitled,
"Annual Limits on Intake (ALI) and Derived Air Concentrations
(DAC) of Radionuclides for Occupational Exposure; Effluent
Concentrations; Concentrations for Release to Sanitary Sewerage",
is made a part of this section and is available from the
department. [Eff 11/12/99] (Auth: HRS §§321-10, 321-11, 321-71)
(Imp: HRS §§321-1, 321-11(21), 321-71)