HAR §11-45-65
HAR §11-45-65. Exceptions to posting requirements
Cite as Haw. Code R. § 11-45-65
(a) A
licensee is not required to post caution signs in areas or rooms
containing sources of radiation for periods of less than eight
hours, if each of the following conditions is met:
(1)
The sources of radiation are constantly attended
during these periods by an individual who takes the
precautions necessary to prevent the exposure of
individuals to sources of radiation in excess of the
limits established in this subchapter; and
(2)
The area or room is subject to the licensee's control.
(b)
Rooms or other areas in hospitals that are occupied by
patients are not required to be posted with caution signs pursuant
to this section provided that the patient could be released from
confinement pursuant to subchapter 7.
(c)
A room or area is not required to be posted with a
caution sign because of the presence of a sealed source provided
the radiation level at thirty centimeters from the surface of the
sealed source container or housing does not exceed 0.005 rem (0.05
millisieverts) per hour.
(d)
A room or area is not required to be posted with a
caution sign because of the presence of a diagnostic x-ray system
used solely for healing arts purposes. [Eff 11/12/99] (Auth:
HRS §§321-10, 321-11, 321-71) (Imp: HRS §§321-1, 321-11(21),
321-71)