HAR §11-501-14
HAR §11-501-14. Air-cleaning
Length: 341 wordsOfficial source
Cite as Haw. Code R. § 11-501-14
(a) Any owner or
operator who uses air cleaning, as specified in
sections 11-501-4(a), 11-501-6(b)(1), 11-501-
7(c)(3)(A)(ii), 11-501-7(c)(4)(B), 11-501-7(c)(6)(E),
11-501-8(2)(B), 11-501-11(c)(1)(A), 11-501-12(1)(A)
(ii), 11-501-12(1)(B)(ii), and 11-501-17(5) shall:
(1)
Use fabric filter collection devices,
except as noted in subsection (b), doing
all of the following:
(A)
Ensuring that the airflow
permeability, as determined by ASTM
Method D737-75, does not exceed 9
m
3/min/m
2(30 ft
3/min/ft
2) for woven
fabrics or 11
m
3/min/m
2(35 ft
3/min/ft
2)
for felted fabrics;
(B)
Ensuring that felted fabric weighs at
least 475 grams per square meter
(fourteen ounces per square yard) and
is at least 1.6 millimeters (one-
sixteenth inch) thick throughout; and
(C)
Avoiding the use of synthetic fabrics
that contain fill yarn other than that
which is spun;
(2)
Properly install, use, operate, and
maintain all air-cleaning equipment
authorized by this section. Bypass devices
may be used only during upset or emergency
conditions and then only for so long as it
takes to shut down the operation generating
the particulate asbestos material;
(3)
For fabric filter collection devices
installed after January 10, 1989, provide
for easy inspection for faulty bags; and
(4)
Maintain on-site one operable, backup
negative air device at all times during the
abatement.
(b)
The following are exceptions to section
(a)(1):
(1)
If the use of fabric creates a fire or
explosion hazard, or the director
determines that a fabric filter is not
feasible, the director may authorize as a
substitute the use of wet collectors
designed to operate with a unit contacting
energy of at least 9.95 kilopascals (forty
inches water gage pressure);
(2)
Use a HEPA filter that is certified to be
at least 99.97 per cent efficient for 0.3
micron particles; or
(3)
The director may authorize the use of
filtering equipment other than described in
section (a)(1) and paragraphs (1) and (2)
if the owner or operator demonstrates to
the director's satisfaction that it is
equivalent to the described equipment in
filtering particulate asbestos material.
[Eff ] (Auth: HRS §342P-41)
(Imp: 40 CFR Part 61.152)