HAR §11-501-6
HAR §11-501-6. Standard for manufacturing
Length: 523 wordsOfficial source
Cite as Haw. Code R. § 11-501-6
(a) This
section applies to the following manufacturing
operations using commercial asbestos for the
manufacture of:
(1)
Cloth, cord, wicks, tubing, tape, twine,
rope, thread, yarn, roving, lap, or other
textile materials;
(2)
Cement products;
(3)
Fireproofing and insulating materials;
(4)
Friction products;
(5)
Paper, millboard, and felt;
(6)
Floor tile;
(7)
Paints, coatings, caulks, adhesives, and
sealants;
(8)
Plastics and rubber materials;
(9)
Chlorine utilizing asbestos diaphragm
technology;
(10)
Shotgun shell wads; and
(11)
Asphalt concrete.
(b)
Each owner or operator of any of the
manufacturing operations to which this section applies
shall:
(1)
Discharge no visible emissions to the
outside air from these operations or from
any building or structure in which they are
conducted or from any other fugitive
sources; or use the methods specified by
section 11-501-14 to clean emissions from
these operations containing particulate
asbestos material before they escape or are
vented to the outside air;
(2)
Monitor each potential source of asbestos
emissions from any part of the
manufacturing facility, including air
cleaning devices, process equipment, and
buildings housing material processing and
handling equipment, at least once each day
during daylight hours for visible emissions
to the outside air during periods of
operation. The monitoring shall be by
visual observation of at least fifteen
seconds duration per source of emissions;
(3)
Inspect each air cleaning device at least
once each week for proper operation and for
changes that signal the potential for
malfunctions, including, to the maximum
extent possible without dismantling other
than opening the device, the presence of
tears, holes, and abrasions in filter bags
and for dust deposits on the clean side of
bags. For air cleaning devices that cannot
be inspected on a weekly basis according to
this paragraph, submit to the director, and
revise as necessary, a written maintenance
plan including:
(A)
A maintenance schedule;
(B)
Work to be performed; and
(C)
A recordkeeping plan;
(4)
Maintain records of the results of visible
emission monitoring and air cleaning device
inspections using a format similar to that
shown in Figure 1, entitled "Record of
Visible Emissions" and Figure 2, entitled
"Air Cleaning Device Inspection Checklist",
both dated June 1, 1998 and located at the
end of this chapter, and include the
following:
(A)
Date and time of each inspection;
(B)
Presence or absence of visible
emissions;
(C)
Condition of fabric filters, including
presence of any tears, holes, and
abrasions;
(D)
Presence of dust deposits on the clean
side of fabric filters;
(E)
Brief description of corrective
actions taken, including date and
time; and
(F)
Daily hours of operation for each air
cleaning device;
(5)
Furnish upon request, and make available at
the affected facility during normal
business hours for inspection by the
director, all records required by this
section;
(6)
Retain a copy of all monitoring and
inspection records for at least two years;
and
(7)
Submit quarterly a copy of the visible
emission monitoring records to the director
if visible emissions occurred during the
report period. Quarterly reports shall be
postmarked by the thirtieth day following
the end of the calendar quarter.
[Eff ] (Auth: HRS § 342P-41)
(Imp: 40 CFR Part 61.144)