HAR §11-503-1
HAR §11-503-1. Definitions
Length: 838 wordsOfficial source
Cite as Haw. Code R. § 11-503-1
As used in this chapter:
"ACM" means asbestos-containing material.
"Asbestos-containing material" means any material
or product which contains more than one per cent
asbestos.
"Asbestos contractor" means any person or
contracting firm possessing a valid asbestos contractor
license pursuant to chapter 16-77, Hawaii
Administrative Rules.
"Category I nonfriable ACM" means asbestos-
containing packings, gaskets, resilient floor covering,
and asphalt roofing products containing more than one
per cent asbestos as determined using the method
specified in 40 CFR Part 763, Subpart F, Appendix A,
Section I, as referenced in section 11-501-3.
"Category II nonfriable ACM" means any material,
excluding category I nonfriable ACM, containing more
than one per cent asbestos as determined using the
methods specified in 40 CFR Part 763, Subpart F,
Appendix A, Section I, as referenced in section 11-501-
3, that, when dry, cannot be crumbled, pulverized, or
reduced to powder by hand pressure.
"Contractor/Supervisor" means any abatement
workerwho has been certified by the department under
these rules to ensure that abatement projects are
conducted in accordance with Federal and State
requirements.
"Demolition" means the wrecking, taking out or
intentional burning of any load-supporting structural
member of a facility together with any related handling
operations.
"Department" means the department of health, State
of Hawaii.
"Director" means the director of the department of
health, State of Hawaii, or the director’s duly
authorized agent.
"Facility" means any institutional, commercial,
public, industrial, or residential structure,
installation, or building (including any structure,
installation, or building containing condominiums or
individual dwelling units operated as a residential
cooperative, but excluding residences or residential
cooperatives that have four or fewer total dwelling
units); any ship; and any active or inactive waste
disposal site. For purposes of this definition, any
building, structure, or installation that contains a
loft used as a dwelling is not considered a residential
structure, installation, or building. Any structure,
installation, or building that was previously subject
to federal requirements pursuant to 40 CFR Part 61,
Subpart M, is not excluded, regardless of its current
use or function.
"Facility component" means any part of a facility,
including equipment, boilers, pipes, furnaces, ducts,
tanks, reactors, turbines, or structural members.
"Friable asbestos material" means any material
containing more than one per cent asbestos as
determined using the method specified in 40 CFR Part
763, Subpart F, Appendix A, Section I, as referenced in
section 11-501-3, that, when dry, can be crumbled,
pulverized, or reduced to powder by hand pressure.
These include sprayed-on or troweled-on fireproofing,
acoustic ceiling material and ceiling tiles, linoleum
and linoleum backing, thermal system insulation, non-
asphalt-saturated roofing felts, asbestos-containing
paper, and joint compound. Materials that have been
rendered to a crumbled, pulverized, or powdered state,
when dry, by crushing, sanding, sawing, shot-blasting,
or other demolition or renovation techniques are
friable, which include category I non-friable asbestos
containing material. Materials in which the asbestos
fibers are bound into a matrix that have been rendered
to a crumbled, pulverized, or powdered state, when dry,
by crushing, sanding, sawing, shot-blasting, severe
weathering, or other demolition or renovation
techniques are friable, which include category II
nonfriable ACM.
"Inspector" means a person certified to identify
asbestos-containing building material and to assess its
physical condition.
"Management planner" means any person certified to
use data gathered by inspectors to assess the current
or potential hazard posed by asbestos-containing
material, to determine the appropriate response
actions, and to develop a schedule for implementing
these response actions.
"Notification" means submittal of a notice of
intent to conduct demolition or renovation in
facilities pursuant to section 11-501-7. For purposes
of this definition, a “notification” shall be limited
to each individual project and shall extend no further
than the premise boundaries.
"Project designer" means a person who is certified
to determine how asbestos abatement work should be
conducted.
"Project monitor" means a person who is certified
to take air clearance samples, perform visual
inspections of the job-site and ensure compliance with
specifications and regulations.
"RACM" means regulated asbestos-containing
material.
"Regulated asbestos-containing material" means:
(1)
Friable asbestos material;
(2)
Category I nonfriable ACM that has become
friable;
(3)
Category I nonfriable ACM that will be or has
been subjected to sanding, drilling,
grinding, cutting, abrading, or any other
activity that may render the material
friable; or
(4)
Category II nonfriable ACM that may become or
has become crumbled, pulverized, or reduced
to powder by the forces expected to act on
the material in the course of demolition or
renovation operations regulated by this
chapter.
"Renovation" means altering a facility of one or
more facility components in any way, including the
stripping or removal of RACM from a facility component.
Operations in which load-supporting structural members
are wrecked or taken out are demolitions.
"Removal" means to take out RACM or facility
components that contain or are covered with RACM from
any facility.
"Training provider" means one who is accredited to
provide training courses pursuant to Chapter 504.
"Worker" means any person who is certified by the
department to engage in abatement activities.
[Eff ] (Auth: HRS §342P) (Imp: 40 CFR